The 200-WS-21-A Dual Set Point Wind Alarm includes a rotating cup style anemometer (200-WS-01B) 
and internal alarm buzzer. Two independently controlled relays are provided to operate external 
equipment such alarm lights or sirens. The Wind Alarm can function as an irrigation or fountain over-
ride controller. 
 
The back-lit LCD display is easily visible through the transparent cover. With the cover removed the 
unit is programmed by push-button controls without the need to connect a computer. DIP switch 
settings select the units (mph or kph) and enable/disable the buzzer. 
 
Each alarm channel has three programmable settings:  

Delay before Alarm  0-99 seconds above threshold before alarm activation 

(Default 15 sec)  

Alarm Set Point 

Wind speed threshold for the alarm   

 

 

(Default 15 mph) 

Delay after Alarm 

0-99 seconds below threshold before alarm de-activation   (Default 15 sec) 

 

When in alarm mode, a blinking LED indicates which relay(s) are active. Each relay can be connected in 
the normally open or the normally closed mode. 

It is the responsibility of the installer to properly 

insulate any connections to the relay terminals, especially if high voltages are present. It is also 
important to provide an earth grounding wire to protect the controller from static discharge, 
whether or not the relays are connected.

 

3

 

TECHNICAL SPECIFICATION 

 
The anemometer is rated for wind speeds up to 125 miles per hour and has a starting threshold of 
approximately 1.2 mile per hour. The Wind Alarm LCD can display speeds up to 99.9 mph, but the 
control logic continues to operate above this limit. 
 
The controller requires a nominal 12V ac or dc power supply. The 200-WS21P power pack (sold 
separately) is suitable in most applications, and comes with the proper terminals for easy connection. 

 

Содержание 200-WS-01B

Страница 1: ...200 WS 21 A User Manual Dual Set Point Wind Alarm Phone 530 823 7185 USA Toll Free 800 321 3577 Fax 530 823 8997 Email nova novalynx com Website www novalynx com...

Страница 2: ...the case of delicate or sensitive items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging Plea...

Страница 3: ...UP and DOWN Buttons 6 4 2 3 CLEAR Button 7 4 2 4 GO Button 7 4 3 Programming 7 4 4 DIP Switch Settings 7 5 ANEMOMETER INSTALLATION 8 5 1 Anemometer Siting Considerations 8 5 2 Anemometer Mounting 8 5...

Страница 4: ...kph and enable disable the buzzer Each alarm channel has three programmable settings Delay before Alarm 0 99 seconds above threshold before alarm activation Default 15 sec Alarm Set Point Wind speed t...

Страница 5: ...ock outs in back surface for screw mounting to a panel Dimensions 5 12 x 6 25 x 2 95 inch 13 0 x 15 9 x 7 5 cm Weight Shipping 1 lbs 0 45 kg 2 lbs 0 9 kg 200 WS 01B Anemometer Specification Measuremen...

Страница 6: ...osition Refer to the DIP Switch Settings section of the manual to correct this situation 4 2 Menu Navigation Locate the programming buttons below the display 4 2 1 MENU Button Press the MENU button On...

Страница 7: ...displayed on the channel 1 value see Program channel 1 above Press the UP or DOWN buttons to change the wind speed threshold for channel 1 3 Press MENU again The blinking block cursor will move to ch...

Страница 8: ...he object Roof mounted sensors should be placed on the upwind side of the building and away from all exhaust vents If the sensor is located on top of a building the sensor height should be 1 5 x H whe...

Страница 9: ...st direct manner Leave a drip loop of cable below the entry point to the equipment enclosure to help keep moisture out Fasten the cable to the mast with cable ties to prevent whipping during high velo...

Страница 10: ...INSTALLATION 6 1 Controller Location To be effective the Wind Alarm controller must be in a location where one can view the display and hear the alarm At the same time it should not be accessible to...

Страница 11: ...earth ground an electrical box with an earth connection or a metal cold water pipe that actually enters the ground Failure to provide a ground may cause erratic operation and make the system more vul...

Страница 12: ...d the Wind Alarm to the settings you desire and the system is operating properly before you connect power to your external devices 8 ALARM FUNCTIONS The Wind Alarm controller must be in Operating Mode...

Страница 13: ...Dn Clr Go PROGRAMMING BUTTONS MODE WIND UNITS TEMP UNITS BUZZER WIND MPH DEG F BUZZ TEMP KPH DEG C SILENT ON OFF Wt Wu Tu Si DIP SETTINGS DUAL SET POINT WINDALARM 200 WS 21A Alarms OFF Red Black Shiel...

Отзывы: