Novalynx 200-WS-01B Скачать руководство пользователя страница 2

NovaLynx Corporation________________________________________________________________________________ 

 

 

 
200-WS-21-A 

Page 2 

November 2018 

 

Receiving and Unpacking

 

 

Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation 
immediately concerning any discrepancy. Inspect equipment to detect any damage that may have 
occurred during shipment. In the event of damage, any claim for loss must be filed immediately with 
the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee 
to contact NovaLynx Corporation for instructions. 

 

Returns

 

 

If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 
p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned 
equipment a description of the problem and the name, address, and daytime phone number of the 
sender. Carefully pack the equipment to prevent damage or additional damage during the return 
shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing 
facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service 
and obtain assistance with the packaging. Please write the RA# on the outside of the box. 

 

Warranty

 

 

NovaLynx Corporation warrants that its products are free from defects in material and workmanship 
under normal use and service for a period of one year from the date of shipment from the factory. 
NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) 
replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx 
Corporation's liability exceed product's original purchase price. This warranty does not apply to any 
equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been 
subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of 
all warranties of fitness and in lieu of the warranty of merchantability. 

 

Address

 

 

NovaLynx Corporation 
431 Crown Point Circle, Suite 120 
Grass Valley, CA 95945-9531 USA 
Phone: (530) 823-7185 
Fax: (530) 823-8997 
Email: [email protected] 
Website: www.novalynx.com

 

 

Copyright © 1988-2018 by NovaLynx Corporation

 

 

Содержание 200-WS-01B

Страница 1: ...200 WS 21 A User Manual Dual Set Point Wind Alarm Phone 530 823 7185 USA Toll Free 800 321 3577 Fax 530 823 8997 Email nova novalynx com Website www novalynx com...

Страница 2: ...the case of delicate or sensitive items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging Plea...

Страница 3: ...UP and DOWN Buttons 6 4 2 3 CLEAR Button 7 4 2 4 GO Button 7 4 3 Programming 7 4 4 DIP Switch Settings 7 5 ANEMOMETER INSTALLATION 8 5 1 Anemometer Siting Considerations 8 5 2 Anemometer Mounting 8 5...

Страница 4: ...kph and enable disable the buzzer Each alarm channel has three programmable settings Delay before Alarm 0 99 seconds above threshold before alarm activation Default 15 sec Alarm Set Point Wind speed t...

Страница 5: ...ock outs in back surface for screw mounting to a panel Dimensions 5 12 x 6 25 x 2 95 inch 13 0 x 15 9 x 7 5 cm Weight Shipping 1 lbs 0 45 kg 2 lbs 0 9 kg 200 WS 01B Anemometer Specification Measuremen...

Страница 6: ...osition Refer to the DIP Switch Settings section of the manual to correct this situation 4 2 Menu Navigation Locate the programming buttons below the display 4 2 1 MENU Button Press the MENU button On...

Страница 7: ...displayed on the channel 1 value see Program channel 1 above Press the UP or DOWN buttons to change the wind speed threshold for channel 1 3 Press MENU again The blinking block cursor will move to ch...

Страница 8: ...he object Roof mounted sensors should be placed on the upwind side of the building and away from all exhaust vents If the sensor is located on top of a building the sensor height should be 1 5 x H whe...

Страница 9: ...st direct manner Leave a drip loop of cable below the entry point to the equipment enclosure to help keep moisture out Fasten the cable to the mast with cable ties to prevent whipping during high velo...

Страница 10: ...INSTALLATION 6 1 Controller Location To be effective the Wind Alarm controller must be in a location where one can view the display and hear the alarm At the same time it should not be accessible to...

Страница 11: ...earth ground an electrical box with an earth connection or a metal cold water pipe that actually enters the ground Failure to provide a ground may cause erratic operation and make the system more vul...

Страница 12: ...d the Wind Alarm to the settings you desire and the system is operating properly before you connect power to your external devices 8 ALARM FUNCTIONS The Wind Alarm controller must be in Operating Mode...

Страница 13: ...Dn Clr Go PROGRAMMING BUTTONS MODE WIND UNITS TEMP UNITS BUZZER WIND MPH DEG F BUZZ TEMP KPH DEG C SILENT ON OFF Wt Wu Tu Si DIP SETTINGS DUAL SET POINT WINDALARM 200 WS 21A Alarms OFF Red Black Shiel...

Отзывы: