Novalynx 200-WS-01B Скачать руководство пользователя страница 1

200-WS-21-A  

User Manual 

 
 

 

 

 

 

Dual Set Point Wind Alarm

 

 

 

 

 

 

 

 

 

Phone

 (530) 823-7185   

USA Toll Free

 (800) 321-3577   

Fax

 (530) 823-8997 

Email

 

[email protected]

   

Website

 www.novalynx.com

 

 

Содержание 200-WS-01B

Страница 1: ...200 WS 21 A User Manual Dual Set Point Wind Alarm Phone 530 823 7185 USA Toll Free 800 321 3577 Fax 530 823 8997 Email nova novalynx com Website www novalynx com...

Страница 2: ...the case of delicate or sensitive items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging Plea...

Страница 3: ...UP and DOWN Buttons 6 4 2 3 CLEAR Button 7 4 2 4 GO Button 7 4 3 Programming 7 4 4 DIP Switch Settings 7 5 ANEMOMETER INSTALLATION 8 5 1 Anemometer Siting Considerations 8 5 2 Anemometer Mounting 8 5...

Страница 4: ...kph and enable disable the buzzer Each alarm channel has three programmable settings Delay before Alarm 0 99 seconds above threshold before alarm activation Default 15 sec Alarm Set Point Wind speed t...

Страница 5: ...ock outs in back surface for screw mounting to a panel Dimensions 5 12 x 6 25 x 2 95 inch 13 0 x 15 9 x 7 5 cm Weight Shipping 1 lbs 0 45 kg 2 lbs 0 9 kg 200 WS 01B Anemometer Specification Measuremen...

Страница 6: ...osition Refer to the DIP Switch Settings section of the manual to correct this situation 4 2 Menu Navigation Locate the programming buttons below the display 4 2 1 MENU Button Press the MENU button On...

Страница 7: ...displayed on the channel 1 value see Program channel 1 above Press the UP or DOWN buttons to change the wind speed threshold for channel 1 3 Press MENU again The blinking block cursor will move to ch...

Страница 8: ...he object Roof mounted sensors should be placed on the upwind side of the building and away from all exhaust vents If the sensor is located on top of a building the sensor height should be 1 5 x H whe...

Страница 9: ...st direct manner Leave a drip loop of cable below the entry point to the equipment enclosure to help keep moisture out Fasten the cable to the mast with cable ties to prevent whipping during high velo...

Страница 10: ...INSTALLATION 6 1 Controller Location To be effective the Wind Alarm controller must be in a location where one can view the display and hear the alarm At the same time it should not be accessible to...

Страница 11: ...earth ground an electrical box with an earth connection or a metal cold water pipe that actually enters the ground Failure to provide a ground may cause erratic operation and make the system more vul...

Страница 12: ...d the Wind Alarm to the settings you desire and the system is operating properly before you connect power to your external devices 8 ALARM FUNCTIONS The Wind Alarm controller must be in Operating Mode...

Страница 13: ...Dn Clr Go PROGRAMMING BUTTONS MODE WIND UNITS TEMP UNITS BUZZER WIND MPH DEG F BUZZ TEMP KPH DEG C SILENT ON OFF Wt Wu Tu Si DIP SETTINGS DUAL SET POINT WINDALARM 200 WS 21A Alarms OFF Red Black Shiel...

Отзывы: