60
OM-C3 11/21
Service and Maintenance - As Required
Replacing Air Cleaner Filter Element
IMPORTANT:
Replace the element after 10 cleanings.
1. Loosen clamp (A) and remove filter element.
2. Install new filter element and tighten clamp.
Replacing Dry Air Cleaner Element
IMPORTANT:
ALWAYS REPLACE primary air cleaner
element when air restriction indicator (A) shows vacuum
of 625 mm (25 in.) H2O, or when reset button has popped
up (if equipped). Also replace element if it is torn, or
visibly dirty.
1. Release air filter assembly clamps (A) and remove
cover.
IMPORTANT:
Insure all air intake connections are
secure to prevent ingestion of abrasive dirt and dust into
the system, causing possible engine damage.
2. Install new air filter element (B), install cover and
engage clamps.
Filter element
Replace air filter element. Air filter assembly clamps
(A), Air filter elements (B)