OM-C3 11/21
17
GENERATOR SET POWER UNITS
To assure that your engine will deliver efficient generator
operation when needed, start engine and run at rated
speed (with 50%—70% load) for 30 minutes every 2
weeks. DO NOT allow engine to run extended period of
time with no load.
AUXILIARY GEAR DRIVE LIMITATIONS
IMPORTANT:
When attaching a sea water pump or
other accessory to be driven by the auxiliary gear drive
(A) (engine timing gear train at front of engine), power
requirements of the accessory must be limited to values
listed below:
• 30 kW (40 hp) Continuous Operation
• 37 kW (50 hp) Intermittent Operation
A—Auxiliary Gear Drive
Engine Operation