LUBRICATION

Break-in oil

1.  Use one of the following during the fi rst 100 hours 

of operation:

 

a.  John Deere Engine Break-In Oil

 

b.  API Service CC, CD, or CE oil

 c. 

ACEA 

Specifi cation E1 or E2

2. 

Do not use

 John Deere PLUS-50 oil or engine oils 

meeting API CI-4, CH-4, CG-4, CF-4, or CF-2, 
ACEA E5, E4, or E3 performance levels during 
the fi rst 100 hours of operation of a new or rebuilt 
engine.  These oils will not allow the engine to 
break-in properly.

Lubrication - General

1.  Use only clean, high quality lubricants stored in 

clean containers in a protected area.

2.  These oils are acceptable after the fi rst 100 hours:
 

a.  API Service Catagory CI-4 or CH-4 oils.

 

b.  ACEA Oil Sequence E4 or E5.

 

d.  ACEA Oil Sequence E3.

3.  Use the proper weight oil for your average operation 

temperature, multi-viscosity diesel engine oils are 
preferred.  Quality and sulfur content must comply 
with local existing emission regulations.

4.  Some increase in oil consumption may be expected 

when SAE 5W and SAE 5-20W oils are used. Check 
oil level frequently.

5.  Never put additives or fl ushing oil in crankcase.

SP1.  CHECK ENGINE OIL LEVEL

1.  Check the oil level in the crankcase, with the oil 

dipstick, daily.

2.  The oil level must be between the “Waffl ed area” 

and the “add”. Never allow the level to go below the 
“add”. 

3.  Always add the same viscosity of oil as is already in 

the crankcase.

SP2. OIL CHANGES

1.  Using the oil recommended above, change the engine 

oil and fi lter after the fi rst 50 hours of operation, the 
fi rst 100 hours and every 250 hours thereafter.

2.  During intermittent cold weather operation, change oil 

every 100 hours or six weeks, whichever comes fi rst.

3.  Change oil at any seasonal change in temperature 

when a new viscosity of oil is required. 

 

a.  Remove plug from outlet in base frame. Screw in 

 

 

owner-supplied drain hose.

 

b.  Open valve at oil pan outlet.  After oil has been 

 

 

drained into suitable container, close valve, remove 

 

 

drain hose and replace plug in base frame outlet.

 c. 

Refi ll engine with recommended oil.

4.  Engine Lube Oil Capacity:

SP3. CHANGING OIL FILTER

1.  Change the lube oil fi lter every 250 hours.
2. Use 

fi lter wrench to remove old fi lter. Dispose of 

fi lter in approved manner.

3.  Make sure the gasket from the old fi lter is removed 

and discarded.

4.  Lubricate the rubber gasket on the new fi lter and screw 

it on nipple until gasket meet the sealing surface.

5.  Using hands only, no wrench, tighten fi lter one-half turn 

farther. Overtightening can do damage to fi lter housing.

6.  Fill engine with recommended oil. Start engine and 

check for leakage. Stop engine and check oil level. 
Add additional oil if necessary.

SP4. AIR CLEANER

1.  Inspect air cleaner every 100 hours. Replace air 

cleaner element every 500 hours. 

2.  Clean the rubber tube at the cleaner. Loosen the hose 

clamp and the attaching strip for the cleaner.

3.  Make sure the rubber tube is in good condition and 

that new fi lter is absolutely clean and installed 

 properly.
4.  Start the engine and check for leaks.

 

NOTE:  Make absolutely sure no impurities enter the 

engine while changing the element. Do not run the 

engine with the air cleaner removed.

 Air 

Single 

Multi

 Temperature 

Viscosity 

Viscosity

 Above 

32°F

 (0°C) 

SAE-30W SAE15-40W

  -10°F to 32°F
  (-23°C to 0°C) 

SAE-10W SAE10-30W

 
 Below 

-10°F

 (-23°C) 

SAE-5W SAE5-20W

 

NL1064D,T1,T2, H1      14.7 liters 

15.5 qts.

 

NL1066T 

    20.0 liters 

21.1 qts.

  NL1066H1,H2,H3 

    31.5 liters    

33.3 qts.

Servicing

Содержание and NL1066H3

Страница 1: ...ONL2 2 For Models NL1064D NL1064T1 NL1064T2 NL1064H1 NL1066T NL1066H1 NL1066H2 and NL1066H3 OPERATOR S MANUAL Marine Generators Marine Diesel Engines Land Based Generators...

Страница 2: ...other reproductive harm CALIFORNIA Proposition 65 Warning Northern Lights 4420 14th Avenue N W Seattle WA 98107 Tel 206 789 3880 Fax 206 782 5455 Copyright 2013 Northern Lights Inc All rights reserve...

Страница 3: ...l 16 Checking Oil 16 Oil Changes 16 Changing Oil Filter 16 Air Filter 16 Belt Tension 17 Valve Clearances 18 Fuels General 19 Crankshaft Vibration Damper 6 Cyl 20 Fuel Filters 19 20 Proprietary Inform...

Страница 4: ...h a mechanically controlled fuel system NL 1064 or 1066 Northern Lights turbocharged industrial generator set with a John Deere Powertech Tier II 4045 engine block with a mechanically controlled fuel...

Страница 5: ...afety signs Keep signs in good and clean condition Replace missing or damaged signs Be sure new equipment components and repair parts include the current safety signs For replacement signs proper plac...

Страница 6: ...ving parts have stopped before making any adjustments connections or performing any other type of service to the engine or other driven equipment Prevent accidental discharge of starting fluids by sto...

Страница 7: ...olyte is poisonous and strong enough to burn skin eat holes into clothing and other materials and cause blindness if splashed into eyes To Avoid Hazards Fill batteries only in well ventilated areas We...

Страница 8: ...ilated Dispose of paint and solvent properly Service Cooling System Safely Opening a pressurized cooling system can release explosive fluids and causing serious burns Before opening any pressurized co...

Страница 9: ...source components between the high pressure fuel pump and nozzles on engines with high pressure fuel systems ONLY AUTHORIZED TECHNICIANS CAN PERFORM REPAIRS ON AN HIGH PRESSURE FUEL INJECTION SYSTEMS...

Страница 10: ...er or other material cannot be achieved at the local supply valve shut off valves further back in the system and re check the bleed off point until complete shut off is achieved Affix a DO NOT OPERATE...

Страница 11: ...ONL2 2 7 13 9 Notes...

Страница 12: ...hroud 7 Alternator 8 Vibration Mount 9 Lube Oil Filter 10 Fuel Manifold 11 Lube Oil Dipstick 12 Starter 13 Fuel Filter 14 Turbocharger 15 Exhaust Manifold 16 Electronic Control Unit Component Location...

Страница 13: ...ator Shroud Figure 3 4 NL1066T Electronically Controlled Fuel System 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 17 18 8 Alternator 9 Vibration Mount 10 Lube Oil Filter 11 Low Oil Level Gauge optional 12...

Страница 14: ...l 9 Alternator 10 Oil Filter 11 Dipstick 12 Low Oil Level Gauge optional 13 Fuel Filter Water Separator optional 14 Fuel Filter 15 Fuel Manifold 16 Secondary Fuel Filter Component Locations Figures 5...

Страница 15: ...t the engine hold this switch in the START position until the engine is running After the engine starts release the switch and it will return to RUN position To stop the engine hold the switch in the...

Страница 16: ...perature is above 205 F 97 C shut off the engine immediately Operating Procedures BEFORE STARTING 1 Check the water level by removing the pressure cap from the expansion tank In order to give the cool...

Страница 17: ...th minimal idling to help seat engine components properly 3 Constantly check the engine temperature and oil pressure gauges 4 Oil consumption is greater during break in as piston rings and cylinder li...

Страница 18: ...k and clean radiator SP23 Test thermostats SP31 Adjust variable speed droop Mechanical Engines Only 1 Change the oil and filter before the first 100 hours of operation during engine break in 2 Perform...

Страница 19: ...tion SP9 Change primary fuel filter element SP10 Change secondary fuel filter SP11 Check injectors SP13 Check turbocharger air oil cooling lines for leakage SP14 Check turbocharger boost pressure SP16...

Страница 20: ...oil every 100 hours or six weeks whichever comes first 3 Change oil at any seasonal change in temperature when a new viscosity of oil is required a Remove plug from outlet in base frame Screw in owner...

Страница 21: ...ed by permission of Deere Company c2005 Deere Company All rights reserved RG10556 Figure 9 A Belt Tension Gauge B Capscrew C Capscrew Note If an automatic spring tensioner is used a belt tension gauge...

Страница 22: ...ke Valve 0 014 0 36 mm Exhaust Valve 0 018 in 0 46 mm 5 If the valves need adjusting loosen the jam nut A on Figure 12 on the rocker arm adjusting screw Turn the adjusting screw until you feel a sligh...

Страница 23: ...n 6 Biodiesel Biodiesel involves the transesterification of vegetable oils or animal fats Mainly in the U S soybean methyl ester is used SME but in Europe mainly rapeseed canola methyl ester is made R...

Страница 24: ...Figure 17 B counter clockwise until the filter cartridge Figure 17 C slides out NOTE Before installing a new filter cartridge make sure the surfaces where the cartridge comes in contact with the moun...

Страница 25: ...leaning Tool JD258 Pilot Tool a Before removal carefully remove all dirt from the cylinder head around fuel injection nozzles Clean with compressed air to prevent dirt from entering the cylinders or v...

Страница 26: ...ug if installed previously from nozzle bore in cylinder head and blow out bore with compressed air b Make sure that the sealing surface of the cylinder head on which the seal washer will be resting is...

Страница 27: ...A and fuel supply line Figure 21 C Figure 21 Reproduced by permission of Deere Company c 2005 Deere Company All rights reserved RG5659 Servicing 4 Disconnect all fuel delivery pressure lines Figure 21...

Страница 28: ...s onto pump mounting studs Tighten nuts three turns only so that pump will not fall off mounting studs NOTE The pump drive gear should begin to move forward away from engine front plate with the pump...

Страница 29: ...de between turbo and engine can be found by applying soapy water to the air line 4 Tighten the hose clamps replace hose or gaskets as required 5 Check to see that the lubrication and cooling lines are...

Страница 30: ...ds are higher than the above given specification the water must be distilled demineralized or deionized before it is used in a cooling system 4 If total hardness is higher than 170 ppm and all other p...

Страница 31: ...ing sizes Pint Part Number 20 00002 1 2 gallon Part Number 20 00003 4 DO NOT use any coolant system additives containing soluble oil COOLANT TESTING 1 Coolant test kits are available to allow on site...

Страница 32: ...battery switch off or break the circuit between the alternator and batteries while the engine is running Regulator damage can result 2 DO NOT reverse the polarity of battery cables when installing the...

Страница 33: ...engine is to be stored for a year or longer 3 Crank the engine a few times with a starter with out starting the engine 4 Remove and clean batteries 5 All engine openings should be sealed with plastic...

Страница 34: ...dealer Injection pump not getting fuel or air in fuel system Check fuel flow at supply pump or bleed fuel system DC ELECTRICAL SYSTEM Battery Will Not Charge Loose or corroded connections Clean and ti...

Страница 35: ...tly Below normal engine temperature Remove and check thermostat Clogged primary fuel filter element Clean or replace filter element Clogged secondary fuel filter element Replace secondary filter eleme...

Страница 36: ...nkcase to proper level Improper type of oil Drain and fill crankcase with correct oil Partially plugged oil filter Replace filter High Oil Consumption Break in period Oil consumption decreases after b...

Страница 37: ...ONL2 2 7 13 35 AC Wiring Diagram A C Wiring All voltages with a SX460 Voltage Regulator Drawing B 5703C...

Страница 38: ...ONL2 2 7 13 36 DC Wiring Diagram D C Wiring 12 Volt Standard Ground for NL1064D Drawing C 5775...

Страница 39: ...ONL2 2 7 13 37 DC Wiring Diagram D C Wiring 24 Volt Standard Ground for NL1064D Drawing C 5776...

Страница 40: ...ONL2 2 7 13 38 Notes...

Страница 41: ...4420 14th Ave NW Seattle WA 98107 Tel 206 789 3880 1 800 762 0165 www northern lights com Northern Lights and Lugger are registered trademarks of Northern Lights Inc 2013 All rights reserved Litho USA...

Отзывы: