General Policy

To avoid dangerous or hazardous situations, refrain from 
any of the following:
• Removing or bypassing a guard or other safety device
• Placing any part of your body in a position where you 
could be caught by moving machinery.
• Cleaning or oiling machinery when in operation.
• Adjusting circuits, chillers, pumps, air handlers, valves, 
circuit breakers or fans while in operation.
• Working on piping or high pressure systems.

Lock Out/Tag Out Instructions - 

Electrical Equipment

Be sure the equipment’s ON/OFF switch is in the OFF 
position and is unplugged from any electrical source before 
attempting to perform any type of work on the equipment.  
Obtain an electrical plug cap cover with a lockset.  Secure 
the plug terminal end using the electrical plug lockout cap.  
Lock the cap and retain the key.

If the equipment is directly wired into an electrical box with 
a shut off switch, obtain a lock pad and/or the appropriate 
colored tags and place the lock and tag through the shut 
off lever.  Retain the key until the repair is completed and 
the machine is safe to start.  Be certain the shut off lever 
is in the OFF position before restarting.  NEVER give a 
lock out key to unauthorized personnel.

If the equipment is directly wired into an electrical box 
without a shut off switch and lock out capability, then a 
circuit breaker lock out will be required.  Obtain a circuit 
lock and tag set.  Install the lock onto the circuit breaker 
box.  Ensure the unit ON/OFF switch is in the OFF position 
before restarting.

Lock Out/Tag Out Instructions - 

Pneumatic and Hydraulic Equipment

For servicing pneumatic and hydraulic equipment, the 
following additional procedures must be implemented, 
following completion of lock out/tag out procedures for 
the unit to be serviced:

Shut off air, water or supply valves at the equipment to 
be serviced.

Check the local bleed-off point for completed release of 
pressurized air, water or oil.

If shutting off of air, water or other material cannot be 
achieved at the local supply valve, shut off valves further 
back in the system and re-check the bleed-off point until  
complete shut-off is achieved.

Affi x a DO NOT OPERATE tag to each valve handle that 
requires shut off.  Each DO NOT OPERATE tag must be 
signed and dated by the authorized technician servicing 
the equipment. 

Lock Out/Tag Out Instructions - 

Air Hose Connected Pneumatic Equipment

Equipment connected to the compressed air system 
through an air hose with a detachable fi tting must be 
shutdown and unplugged.  Excess air must be bled prior 
to removing the air hose, prior to any maintenance or 
repair activities.  

Affi x a DO NOT OPERATE tag to the air hose near the 
detachable fi tting.  Each DO NOT OPERATE tag must be 
signed and dated by the authorized technician servicing 
the equipment.  Check that the equipment cannot be 
operated by activating the ON switch.

Stored Energy

Immediately after applying Lock Out or Tag Out devices, 
ensure that all potentially hazardous stored or residual 
energy is relieved, disconnected, restrained and otherwise 
rendered safe.

Verifi cation of Isolation

Verify the machinery or equipment is actually isolated and 
de-energized prior to beginning work on a machine or on 
equipment that has been locked out.

Restarting Procedures

Follow the procedures below prior to restoring energy:
• Ensure that all machinery or equipment is properly 
reassembled.  Inspect the machinery or equipment to 
verify non-essential items have been removed.
• Ensure that all personnel are safely outside danger 
zones.  Notify personnel that lock out/tag out devices have 
been removed and energy will be reapplied.
• Only authorized personnel may remove lock out/tag out 
devices or notices.  

Scope

During maintenance, repairs or retooling of a Northern Lights generator set, simply turning the machine off or unplugging 
it while it is being worked on does not give enough protection to others who are not performing the maintenance or 
repair.  Many serious accidents happen when someone thought the machine was turned off, or all of its energy was 
safely blocked or released. 

Lock Out / Tag Out Procedures

Added 2-24-12

Содержание and NL1066H3

Страница 1: ...ONL2 2 For Models NL1064D NL1064T1 NL1064T2 NL1064H1 NL1066T NL1066H1 NL1066H2 and NL1066H3 OPERATOR S MANUAL Marine Generators Marine Diesel Engines Land Based Generators...

Страница 2: ...other reproductive harm CALIFORNIA Proposition 65 Warning Northern Lights 4420 14th Avenue N W Seattle WA 98107 Tel 206 789 3880 Fax 206 782 5455 Copyright 2013 Northern Lights Inc All rights reserve...

Страница 3: ...l 16 Checking Oil 16 Oil Changes 16 Changing Oil Filter 16 Air Filter 16 Belt Tension 17 Valve Clearances 18 Fuels General 19 Crankshaft Vibration Damper 6 Cyl 20 Fuel Filters 19 20 Proprietary Inform...

Страница 4: ...h a mechanically controlled fuel system NL 1064 or 1066 Northern Lights turbocharged industrial generator set with a John Deere Powertech Tier II 4045 engine block with a mechanically controlled fuel...

Страница 5: ...afety signs Keep signs in good and clean condition Replace missing or damaged signs Be sure new equipment components and repair parts include the current safety signs For replacement signs proper plac...

Страница 6: ...ving parts have stopped before making any adjustments connections or performing any other type of service to the engine or other driven equipment Prevent accidental discharge of starting fluids by sto...

Страница 7: ...olyte is poisonous and strong enough to burn skin eat holes into clothing and other materials and cause blindness if splashed into eyes To Avoid Hazards Fill batteries only in well ventilated areas We...

Страница 8: ...ilated Dispose of paint and solvent properly Service Cooling System Safely Opening a pressurized cooling system can release explosive fluids and causing serious burns Before opening any pressurized co...

Страница 9: ...source components between the high pressure fuel pump and nozzles on engines with high pressure fuel systems ONLY AUTHORIZED TECHNICIANS CAN PERFORM REPAIRS ON AN HIGH PRESSURE FUEL INJECTION SYSTEMS...

Страница 10: ...er or other material cannot be achieved at the local supply valve shut off valves further back in the system and re check the bleed off point until complete shut off is achieved Affix a DO NOT OPERATE...

Страница 11: ...ONL2 2 7 13 9 Notes...

Страница 12: ...hroud 7 Alternator 8 Vibration Mount 9 Lube Oil Filter 10 Fuel Manifold 11 Lube Oil Dipstick 12 Starter 13 Fuel Filter 14 Turbocharger 15 Exhaust Manifold 16 Electronic Control Unit Component Location...

Страница 13: ...ator Shroud Figure 3 4 NL1066T Electronically Controlled Fuel System 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 17 18 8 Alternator 9 Vibration Mount 10 Lube Oil Filter 11 Low Oil Level Gauge optional 12...

Страница 14: ...l 9 Alternator 10 Oil Filter 11 Dipstick 12 Low Oil Level Gauge optional 13 Fuel Filter Water Separator optional 14 Fuel Filter 15 Fuel Manifold 16 Secondary Fuel Filter Component Locations Figures 5...

Страница 15: ...t the engine hold this switch in the START position until the engine is running After the engine starts release the switch and it will return to RUN position To stop the engine hold the switch in the...

Страница 16: ...perature is above 205 F 97 C shut off the engine immediately Operating Procedures BEFORE STARTING 1 Check the water level by removing the pressure cap from the expansion tank In order to give the cool...

Страница 17: ...th minimal idling to help seat engine components properly 3 Constantly check the engine temperature and oil pressure gauges 4 Oil consumption is greater during break in as piston rings and cylinder li...

Страница 18: ...k and clean radiator SP23 Test thermostats SP31 Adjust variable speed droop Mechanical Engines Only 1 Change the oil and filter before the first 100 hours of operation during engine break in 2 Perform...

Страница 19: ...tion SP9 Change primary fuel filter element SP10 Change secondary fuel filter SP11 Check injectors SP13 Check turbocharger air oil cooling lines for leakage SP14 Check turbocharger boost pressure SP16...

Страница 20: ...oil every 100 hours or six weeks whichever comes first 3 Change oil at any seasonal change in temperature when a new viscosity of oil is required a Remove plug from outlet in base frame Screw in owner...

Страница 21: ...ed by permission of Deere Company c2005 Deere Company All rights reserved RG10556 Figure 9 A Belt Tension Gauge B Capscrew C Capscrew Note If an automatic spring tensioner is used a belt tension gauge...

Страница 22: ...ke Valve 0 014 0 36 mm Exhaust Valve 0 018 in 0 46 mm 5 If the valves need adjusting loosen the jam nut A on Figure 12 on the rocker arm adjusting screw Turn the adjusting screw until you feel a sligh...

Страница 23: ...n 6 Biodiesel Biodiesel involves the transesterification of vegetable oils or animal fats Mainly in the U S soybean methyl ester is used SME but in Europe mainly rapeseed canola methyl ester is made R...

Страница 24: ...Figure 17 B counter clockwise until the filter cartridge Figure 17 C slides out NOTE Before installing a new filter cartridge make sure the surfaces where the cartridge comes in contact with the moun...

Страница 25: ...leaning Tool JD258 Pilot Tool a Before removal carefully remove all dirt from the cylinder head around fuel injection nozzles Clean with compressed air to prevent dirt from entering the cylinders or v...

Страница 26: ...ug if installed previously from nozzle bore in cylinder head and blow out bore with compressed air b Make sure that the sealing surface of the cylinder head on which the seal washer will be resting is...

Страница 27: ...A and fuel supply line Figure 21 C Figure 21 Reproduced by permission of Deere Company c 2005 Deere Company All rights reserved RG5659 Servicing 4 Disconnect all fuel delivery pressure lines Figure 21...

Страница 28: ...s onto pump mounting studs Tighten nuts three turns only so that pump will not fall off mounting studs NOTE The pump drive gear should begin to move forward away from engine front plate with the pump...

Страница 29: ...de between turbo and engine can be found by applying soapy water to the air line 4 Tighten the hose clamps replace hose or gaskets as required 5 Check to see that the lubrication and cooling lines are...

Страница 30: ...ds are higher than the above given specification the water must be distilled demineralized or deionized before it is used in a cooling system 4 If total hardness is higher than 170 ppm and all other p...

Страница 31: ...ing sizes Pint Part Number 20 00002 1 2 gallon Part Number 20 00003 4 DO NOT use any coolant system additives containing soluble oil COOLANT TESTING 1 Coolant test kits are available to allow on site...

Страница 32: ...battery switch off or break the circuit between the alternator and batteries while the engine is running Regulator damage can result 2 DO NOT reverse the polarity of battery cables when installing the...

Страница 33: ...engine is to be stored for a year or longer 3 Crank the engine a few times with a starter with out starting the engine 4 Remove and clean batteries 5 All engine openings should be sealed with plastic...

Страница 34: ...dealer Injection pump not getting fuel or air in fuel system Check fuel flow at supply pump or bleed fuel system DC ELECTRICAL SYSTEM Battery Will Not Charge Loose or corroded connections Clean and ti...

Страница 35: ...tly Below normal engine temperature Remove and check thermostat Clogged primary fuel filter element Clean or replace filter element Clogged secondary fuel filter element Replace secondary filter eleme...

Страница 36: ...nkcase to proper level Improper type of oil Drain and fill crankcase with correct oil Partially plugged oil filter Replace filter High Oil Consumption Break in period Oil consumption decreases after b...

Страница 37: ...ONL2 2 7 13 35 AC Wiring Diagram A C Wiring All voltages with a SX460 Voltage Regulator Drawing B 5703C...

Страница 38: ...ONL2 2 7 13 36 DC Wiring Diagram D C Wiring 12 Volt Standard Ground for NL1064D Drawing C 5775...

Страница 39: ...ONL2 2 7 13 37 DC Wiring Diagram D C Wiring 24 Volt Standard Ground for NL1064D Drawing C 5776...

Страница 40: ...ONL2 2 7 13 38 Notes...

Страница 41: ...4420 14th Ave NW Seattle WA 98107 Tel 206 789 3880 1 800 762 0165 www northern lights com Northern Lights and Lugger are registered trademarks of Northern Lights Inc 2013 All rights reserved Litho USA...