57
SR1001 Installation Guide
Version 8.3.5
LAN Interfaces
The following table provides information about Ethernet interface.
Table 19: E1 WAN Interface
Receive line rate
2.048 Mbps ± 50 ppm (payload = 1.984 Mbps)
Line code
HDB3
Framing
crc
non-crc (ITU G.704)
unframed
Input signal
0 to -32 db
Output signal
ITUG.703
Impedance
75 ohm
120 ohm
Connectors
RJ-48C
Timing
internal
network
Table 20 Specifications: Serial Interface
Input signal
150 mV peak-to-peak minimum
1 V peak-to-peak maximum
Output signal
Electrically balanced with NRZ encoding
Impedance
Transmitter: 330 ohm
Receiver: 110 ohm
Transmission rates
44.7 Mbps
Connectors
50-position Molex
Timing
Looped or internal (selectable)
Clock
Variable
Standards compliance
TIA/EIA-612
TIA/EIA-613
Table 21 Specifications: V.35 Interface
Input signal
150 mV peak-to-peak minimum
1.2 V peak-to-peak maximum
Output signal
Electrically balanced with NRZ encoding
Impedance
Transmitter: 100 ohm
Receiver: 100 ohm
Transmission rates
8 Mbps
Connector
DB-60
Timing
Looped or internal
Clock
Variable
Standards compliance
V.35
Содержание SR1001
Страница 8: ...SR1001 Installation Guide Version 8 3 5 ...
Страница 10: ...SR1001 Installation Guide Version 8 3 5 ...
Страница 12: ...SR1001 Installation Guide Version 8 3 5 ...
Страница 18: ...6 CHAPTER 1 About This Guide Documentation SR1001 Installation Guide Version 8 3 5 ...
Страница 24: ...12 CHAPTER 2 Product Introduction 1001 Serial SR1001 Installation Guide Version 8 3 5 ...
Страница 38: ...26 CHAPTER 3 Installation Operator Interface SR1001 Installation Guide Version 8 3 5 ...
Страница 60: ...48 CHAPTER 4 Configuration Saving Configurations SR1001 Installation Guide Version 8 3 5 ...
Страница 66: ...54 CHAPTER 5 Troubleshooting Diagnostics Tips SR1001 Installation Guide Version 8 3 5 ...