MSC FRU replacement process 7
Media Services Card replacement
NN40010-315
6
Carefully remove the base function tray from the platform base chassis to prevent damage to the cables and
connectors.
7
Place the base function tray on a flat, clean, and static-safe surface.
8
Remove the base function tray bezel:
a
Unfasten the bezel screws from the base function tray face. Place the screws in a safe location.
b
Pull and tip the bezel away from the base function tray until the bezel clips are clear of the base function
tray chassis. Move the bezel in a downward direction between the base function tray latches. Place the
bezel in a safe location.
9
At the front of the base function tray, loosen and remove the Peripheral Component Interconnect (PCI) cover
plate screw (use a #2 Phillips screwdriver). Place the screw in a safe location. (
)
10
Remove the PCI cover plate from the base function tray chassis.
Next Step:
You are ready to remove the MSC; see
“C. Removing the MSC” on page 8
Base function tray with WAN card installed
Perform the following procedure if your BCM has a WAN card installed in the base function tray (
1
With the base function tray partially removed from the platform base chassis, perform
in the preceding procedure.
2
Remove the WAN card.
3
Disconnect the DS30 cable connectors from the MSC.
4
Completely remove the base function tray from the platform chassis.
5
Place the base function tray on a flat, clean, and static-safe surface.
Next Step:
You are ready to remove the MSC.
Figure 3
Remove the PCI cover plate and WAN card before you remove DS30 cables