Chapter 5 — ISDN BRI line and packet data implementation
Page 229 of 492
Option 11C
ISDN BRI Administration and Maintenance
TN
lll ch
lll (0-159) = PRI2 loop number which is connected to the
external packet handler or the Packet Switched Data
Network.
ch (1-30) = the PRI2 channel on which the dedicated
B-channel dedicated connection from the DSL B-channel is
terminated.
TN prompt is given only if call type = PMD.
The PRI channel must be configured in LD17 and
dedicated only to the connection of an external packet
handler.
B2CT
(VCE) (DTA)
PMD
XPMD
B-channel 2 call type
VCE = Circuit switched voice
DTA = Circuit switched data
PMD = B-channel packet data with dedicated connection
from DSL to a PRI channel using external packet handler.
For B2CT = PMD, B-channel packet data must have been
specified at the PH prompt in LD27.
PMD cannot be combined with any other options.
Do not select <cr> which defaults to VCE (circuit switched
voice) and DTA (circuit switched data) which may not run
concurrently with packet data.
XPMD = Delete PMD call types.
Enter <cr> to select voice and data as defaults.
TN
lll ch
lll (0-159) = PRI2 loop number which is connected to the
external packet handler or the Packet Switched Data
Network.
ch (1-30) = the PRI2 channel on which the dedicated
B-channel dedicated connection from the DSL B-channel is
terminated.
TN prompt is given only if call type = PMD.
The PRI channel must be configured in LD17 and
dedicated only to the connection of an external packet
handler.
Prompt
Response
Comment
Содержание Meridian 1 Option 11C
Страница 2: ......
Страница 4: ...553 3011 311 Standard 7 0 May 1999...
Страница 12: ...viii Contents 553 3011 311 Standard 7 0 May 1999...
Страница 14: ...Page x About this guide 553 3011 311 Standard 7 0 May 1999...
Страница 152: ...Page 138 of 492 Chapter 3 Feature packaging and prerequisites 553 3011 311 Standard 7 0 May 1999...
Страница 166: ...Page 152 of 492 Chapter 4 Network clocking 553 3011 311 Standard 7 0 May 1999...
Страница 318: ...Page 304 of 492 Chapter 6 ISDN BRI trunk implementation 553 3011 311 Standard 7 0 May 1999...
Страница 434: ...Page 420 of 492 Chapter 8 Service changes and maintenance 553 3011 311 Standard 7 0 May 1999...
Страница 446: ...Page 432 of 492 Chapter 9 ISDN BRI traffic reports 553 3011 311 Standard 7 0 May 1999...
Страница 492: ...Page 478 of 492 Appendix A 2Mb PRI implementation 553 3011 311 Standard 7 0 May 1999...