Chapter 7 — Meridian Modular Telephones
Page 75 of 136
Meridian 1 Option 11C Compact
Technical Reference Guide
Closet power supply
Closet power can be obtained from an AC transformer for loops of 100 ft.
(30 m) or less, or a DC transformer for loop lengths of 650 ft. (197 m) or less.
An equivalent power source can be used but must maintain isolation of
outputs to the terminal. (Refer to
All terminals must be isolated from the input winding and each terminal must
be isolated from all other terminal windings. A separate winding is required
for each terminal, and grounds should not be connected.
Note: The QUT1 closet power supply source is not compatible with
Meridian Modular Telephones.
The AC source should be rated at 29 V AC, 700 mA isolated. The DC source
should be rated at 42 V DC, 300 mA isolated, with current limiting output of
1 amp.
CAUTION
When using closet power, do not plug the TELADAPT connector into
any equipment (computer, modem, LAN card) other than the Meridian
Modular Telephone, as damage to equipment may result.
Содержание Meridian 1 Option 11C Compact
Страница 3: ...553 3121 100 Standard 2 0 September 1998 ...
Страница 11: ...viii About this guide 553 3121 100 Standard 2 0 September 1998 ...
Страница 21: ...Page 10 of 136 Chapter 1 Provisioning 553 3121 100 Standard 2 0 September 1998 ...
Страница 41: ...Page 30 of 136 Chapter 2 Transmission parameters 553 3121 100 Standard 2 0 September 1998 ...
Страница 63: ...Page 52 of 136 Chapter 6 SDI ports 553 3121 100 Standard 2 0 September 1998 ...
Страница 103: ...Page 92 of 136 Chapter 8 M2250 Attendant Console 553 3121 100 Standard 2 0 September 1998 ...
Страница 107: ...Page 96 of 136 Chapter 9 NTMW05 Digital Line Card 553 3121 100 Standard 2 0 September 1998 ...
Страница 137: ...Page 126 of 136 Chapter 12 NTMW44 Universal Trunk Card 553 3121 100 Standard 2 0 September 1998 ...