Page 42 of 136
Chapter 4 — Power supplies
553-3121-100
Standard 2.0
September 1998
Overvoltage
An OVP (Over-Voltage Protection) circuit shuts down the power supply
when the output voltage exceeds the limits given in Table 23.
Table 23
Nominal and overvoltage limits
All outputs in a shutdown state are reset by the SSC card.
Note: The system power does not automatically reset when there is
overvoltage on the -52V DC output. Manual reset is required. The
manual reset button is located on the faceplate of the SSC card.
Temperature sensor
The NTMW11 Power Supply is sensitive to the temperature of the cabinet
and the system power. A thermostat is located at the top of the power supply
unit. The input breaker trips for temperatures exceeding 175°F (80°C).
Nominal
voltage
Overvoltage
limit
Power supply status
+5.1V
+6.4V
Complete Shutdown
+8.5V
+10.6V
Complete Shutdown
-150V
-187.5V
Complete Shutdown
+15V
+18.7V
Complete Shutdown
-15V
-18.7V
Complete Shutdown
-48V
N/A
N/A
Ring
(Pk V)
150V
Complete Shutdown
-52V
-58V
Complete Shutdown
Содержание Meridian 1 Option 11C Compact
Страница 3: ...553 3121 100 Standard 2 0 September 1998 ...
Страница 11: ...viii About this guide 553 3121 100 Standard 2 0 September 1998 ...
Страница 21: ...Page 10 of 136 Chapter 1 Provisioning 553 3121 100 Standard 2 0 September 1998 ...
Страница 41: ...Page 30 of 136 Chapter 2 Transmission parameters 553 3121 100 Standard 2 0 September 1998 ...
Страница 63: ...Page 52 of 136 Chapter 6 SDI ports 553 3121 100 Standard 2 0 September 1998 ...
Страница 103: ...Page 92 of 136 Chapter 8 M2250 Attendant Console 553 3121 100 Standard 2 0 September 1998 ...
Страница 107: ...Page 96 of 136 Chapter 9 NTMW05 Digital Line Card 553 3121 100 Standard 2 0 September 1998 ...
Страница 137: ...Page 126 of 136 Chapter 12 NTMW44 Universal Trunk Card 553 3121 100 Standard 2 0 September 1998 ...