Page 44 of 136
Chapter 4 — Power supplies
553-3121-100
Standard 2.0
September 1998
•
In the Expansion cabinet
— When the NTMW07 card is in slot 11 & 12
TN 11 03 connects to TN 12 03
(Trunk on Card 11 Unit 03 connects to the telephone on Card 12
Unit 03)
— When the NTMW07 card is in slot 13 & 14
TN 13 03 connects to TN 14 03
(Trunk on Card 13 Unit 03 connects to the telephone on Card 14
Unit 03)
— When the NTMW07 card is in slot 15 & 16
TN 15 03 connects to TN 16 03
(Trunk on Card 15 Unit 03 connects to the telephone on Card 16
Unit 03)
Commercial Power Backup
An Un-interruptible Power Supply (UPS) may be connected to the
Option 11C Compact system in order to provide a continuous supply of
AC-power.
The UPS requirements are based on the following:
•
The NTMW11 Power Supply is rated at 750 VA Maximum
•
The Real Power is 460 W Maximum
•
The Power Factor is approximately 0.6
•
The power-up in-rush surge current is 35A maximum (120 VAC)
A typical 80-line single cabinet system (CPU, Voice Mail, three 24 DLC, one
PRI) will have a UPS load of approximately 360 VA.
Selecting a UPS is a function of the total power to be supplied multiplied by
the total hold-up time desired.
Содержание Meridian 1 Option 11C Compact
Страница 3: ...553 3121 100 Standard 2 0 September 1998 ...
Страница 11: ...viii About this guide 553 3121 100 Standard 2 0 September 1998 ...
Страница 21: ...Page 10 of 136 Chapter 1 Provisioning 553 3121 100 Standard 2 0 September 1998 ...
Страница 41: ...Page 30 of 136 Chapter 2 Transmission parameters 553 3121 100 Standard 2 0 September 1998 ...
Страница 63: ...Page 52 of 136 Chapter 6 SDI ports 553 3121 100 Standard 2 0 September 1998 ...
Страница 103: ...Page 92 of 136 Chapter 8 M2250 Attendant Console 553 3121 100 Standard 2 0 September 1998 ...
Страница 107: ...Page 96 of 136 Chapter 9 NTMW05 Digital Line Card 553 3121 100 Standard 2 0 September 1998 ...
Страница 137: ...Page 126 of 136 Chapter 12 NTMW44 Universal Trunk Card 553 3121 100 Standard 2 0 September 1998 ...