BES50 advanced features configuration
Variable definitions
Variable
Value
VLAN
Select the ID of the configured VLAN. (Range: 1 to 4094)
Name
Type the VLAN name. (Range 1 to 32 characters)
Status
Select to enable the specified VLAN. If the VLAN is not enabled, it
is suspended and therefore does not pass packets.
Port
Port identifier.
Trunk
Trunk identifier.
Tagged
Select if the interface is a member of the VLAN. All packets
transmitted by the port are tagged. Packets carry a tag and
therefore they carry VLAN or CoS information.
Untagged
Select if the interface is a member of the VLAN. All packets
transmitted by the port are untagged. Packets do not carry a tag
and therefore they do not carry VLAN or CoS information. An
interface must be assigned to at least one group as an untagged
port.
Forbidden
Select if the interface is forbidden from automatically joining the
VLAN through GVRP.
None
Select if the interface is not a member of the VLAN. Packets
associated with this VLAN are not transmitted by the interface.
Trunk Member
Indicates if a port is a member of a trunk. To add a trunk to the
selected VLAN, use the last table on the VLAN Static Table page.
Adding static members to VLANs (port index)
Use this procedure to assign VLAN groups to the selected interface as a
tagged member.
Procedure steps
Step
Action
1
From the main menu, choose Application > VLAN > 802.1Q VLAN
> Static Membership by Port.
2
Select the appropriate port or trunk interface.
3
Click Query to display membership information for the interface.
4
From the Non-Member, select a VLAN ID list.
5
Click Add to add the interface as a tagged member.
6
Click Submit.
SMB
Using the Nortel Business Ethernet Switch 50 Series
NN47924-301
01.01
Standard
1.00
October 2006
Copyright © 2006, Nortel Networks
Nortel Networks Confidential
.