Configuring the system clock
37
Navigation
•
"Setting the system clock" (page 37)
•
"Setting daylight saving time" (page 37)
Setting the system clock
Use this procedure to set the system clock manually or automatically.
ATTENTION
Manually set system time is not maintained upon reset of the BES50 hardware
or software.
Procedure steps
Step
Action
1
From the main menu, choose Applications > SNTP.
2
To set time manually:
a. Select Set the system time manually.
b. In the Manual table, type the value for each of the Hours,
Minutes, Seconds, Month, Day, and Year fields.
ATTENTION
The Year field must be at least 2001.
3
To set time automatically:
a. Select Set the system time using Simple Network Time
Protocol (SNTP) automatically.
b. From the Time Zone list, select the appropriate time zone.
c. Complete the settings in the Automatic and SNTP Server tables
as required.
See
"Setting daylight saving time" (page 37)
for details.
4
Click Submit.
—End—
Setting daylight saving time
Use this procedure to configure daylight saving time on the BES50.
Prerequisites
•
Select the automatic system time configuration option.