BES50 installation options
This chapter describes the procedures for optional installation methods
for the Business Ethernet Switch (BES) 50. For standard installation
instructions, see the Business Ethernet Switch 50 Series Quick Install
Guide.
Navigation
•
"Installing the BES50 on a brick or concrete wall" (page 123)
•
"Installing the BES50 on a wood wall" (page 124)
•
"Installing the BES50 on a rack" (page 124)
Installing the BES50 on a brick or concrete wall
Use this procedure to install your BES50 on a brick or concrete wall.
Procedure steps
Step
Action
1
If you mount the switch on a plastered brick or concrete wall, mark
the position of the mounting screws on the wall so they line up with
the two mounting slots on the bottom of the switch.
2
Drill two holes of appropriate size for the wall plugs and screws
(recommended size T3 x 15L). Press the plugs firmly into the drilled
holes until they are flush with the surface of the wall.
3
Insert the screws into the wall plugs leaving about 3 mm (0.12 in.)
clearance from the wall.
4
Position the Customer Provided Equipment (CPE) over the mounting
screws, and then slide it down onto the screws.
—End—