Environmental requirements
17
ESD cable example
To install the ESD discharge cable:
Step
Action
1
Connect the ground lug on the ESD discharge cable to a safe and
suitable earth ground.
2
Briefly connect all RJ-45 cable connectors to the female RJ-45
connector of the ESD discharge cable, then connect each RJ-45
cable connector to the switch.
3
Leave cables connected to the networking equipment. Once cables
are connected to networking equipment, the cables do not build
up charge.
—End—
Environmental requirements
" Nortel Ethernet Routing Switch 5500 Series environmental requirements"
(page 17)
displays the environmental requirements for the individual
switches in this series. Ensure that the area where the switch is installed
and operated will meet these requirements.
Nortel Ethernet Routing Switch 5500 Series environmental requirements
Nortel Ether
net Routing
Switch 5510
Nortel Ether
net Routing
Switch 5520
Nortel Ethernet
Routing Switch
5530
Ambient
Temperature
Between
32 and 113
degrees
Fahrenheit (0
and 45 degrees
Celsius).
Between
32 and 104
degrees
Fahrenheit (0
and 40 degrees
Celsius) for
continuous
operation. This
operational
Between 32 and
122 degrees
Fahrenheit (0
and 50 degrees
Celsius) for
continuous
operation. This
operational
temperature can
Nortel Ethernet Routing Switch 5500 Series
Installation
NN47200-300
2.00
Standard
5.0
7 July 2006
Copyright © 2005 - 2006, Nortel Networks
Nortel Networks Confidential
.