Installing a Nortel Ethernet Routing Switch 5530-24TFD in a rear mounted configuration
23
Mounting the switch
—End—
Installing a Nortel Ethernet Routing Switch 5530-24TFD in a rear
mounted configuration
The Nortel Ethernet Routing Switch 5530-24TFD now features the option of
installing the switch in a rear mounted configuration. This option allows the
switch to be installed with the back panel facing forward.
To install the 5530-24TFD in a rear mounted configuration perform the
following tasks:
Step
Action
1
Attach a bracket to each side of the switch using a #2 Phillips
screwdriver as illustrated in
"Attaching rear mounted switch brackets"
. The bracket with the round holes goes on the right side of
the switch, where the round fan vents are located.