Chapter 16 System Maintenance menus 8 to 10
207
Nortel Business Secure Router 222 Configuration — Advanced
Current Date
This field displays an updated date only when you reenter this menu.
New Date
Enter the new date in year, month and day format. This field is
available when you select
Manual
in the
Time Protocol
field.
Time Zone
Press [SPACE BAR] and then [ENTER] to set the time difference
between your time zone and Greenwich Mean Time (GMT).
Daylight Saving
Time
Daylight Saving Time is a period from late spring to early fall when
many countries set their clocks ahead of normal local time by one
hour to give more daylight time in the evenings. If you use daylight
savings time, then choose
Yes
.
Start Date
(mm-nth-week-hr)
Configure the day and time when Daylight Saving Time starts if you
select
Yes
in the
Daylight Saving
field. The
hr
field uses the
24-hour format. Here are a couple of examples:
Daylight Saving Time starts in most parts of the United States on the
first Sunday of April. Each time zone in the United States starts
using Daylight Saving Time at 2 a.m. local time. So, in the United
States, select
Apr.
,
1st
,
Sun.
and type 02 in the
hr
field.
Daylight Saving Time starts in the European Union on the last
Sunday of March. All of the time zones in the European Union start
using Daylight Saving Time at the same moment (1 a.m. GMT or
UTC). So, in the European Union, select
Mar.
,
Last
,
Sun.
The time
you type in the
hr
field depends on your time zone. In Germany, for
instance, type 02 because Germany's time zone is one hour ahead
of GMT or UTC (GMT+1).
End Date
(mm-nth-week-hr)
Configure the day and time when Daylight Saving Time ends if you
select
Yes
in the
Daylight Saving
field. The
hr
field uses the 24
hour format. Here are a couple of examples:
Daylight Saving Time ends in the United States on the last Sunday
of October. Each time zone in the United States stops using Daylight
Saving Time at 2 a.m. local time. So, in the United States, select
Oct.
,
Last
,
Sun.
and type 02 in the
hr
field.
Daylight Saving Time ends in the European Union on the last
Sunday of October. All of the time zones in the European Union stop
using Daylight Saving Time at the same moment (1 a.m. GMT or
UTC). So, in the European Union, select
Oct.
,
Last
,
Sun.
The time
you type in the
hr
field depends on your time zone. In Germany, for
instance, type 02 because Germany's time zone is one hour ahead
of GMT or UTC (GMT+1).
After you fill in this menu, press [ENTER] at the message “Press ENTER to Confirm or
ESC to Cancel“ to save your configuration, or press [ESC] to cancel.
Table 51
Time and Date Setting Fields
Field
Description
Содержание 222
Страница 14: ...14 Contents NN47922 501 ...
Страница 24: ...24 Tables NN47922 501 ...
Страница 30: ...30 Preface NN47922 501 ...
Страница 46: ...46 Chapter 2 Introducing the SMT NN47922 501 SMT menus at a glance Figure 6 SMT overview ...
Страница 70: ...70 Chapter 3 WAN and Dial Backup Setup NN47922 501 ...
Страница 78: ...78 Chapter 4 LAN setup NN47922 501 ...
Страница 100: ...100 Chapter 6 Remote Node setup NN47922 501 ...
Страница 104: ...104 Chapter 7 IP Static Route Setup NN47922 501 ...
Страница 132: ...132 Chapter 9 Network Address Translation NAT NN47922 501 ...
Страница 154: ...154 Chapter 11 Filter configuration NN47922 501 ...
Страница 158: ...158 Chapter 12 SNMP Configuration NN47922 501 ...
Страница 198: ...198 Chapter 15 Firmware and configuration file maintenance NN47922 501 ...
Страница 212: ...212 Chapter 17 Remote Management NN47922 501 ...
Страница 232: ...232 Appendix B Triangle Route NN47922 501 ...
Страница 252: ...252 Appendix D PPPoE NN47922 501 ...
Страница 260: ...260 Appendix F Hardware specifications NN47922 501 ...
Страница 270: ...270 Appendix G IP subnetting NN47922 501 ...
Страница 308: ...308 Appendix H Command Interpreter NN47922 501 ...
Страница 312: ...312 Appendix I NetBIOS filter commands NN47922 501 ...
Страница 336: ...336 Appendix L Brute force password guessing protection NN47922 501 ...