Requirements for European Operation
114200-E Rev 00
D-3
ARN Expansion Modules Safety Status
ARN expansion modules are upgrade options that provide an additional
synchronous interface. These options can be installed in any ARN model.
Table D-4
lists the safety status of the interconnection point (COM3, COM4,
COM5, COM6, COM7, COM8, and COM9) provided by each of the expansion
modules (Order Nos. CV0004011, CV0004012, CV0004013, CV0004014,
CV0004015, CV0004026, and CV0004027) to the connection of other equipment.
Synchronous Cabling Requirements
Refer to Figures
D-1
through
D-6
and Tables
D-5
through
D-10
for serial interface
cabling information.
Note the following compliance requirements:
•
V.28 compliance requires an Order No. 7837 or 7934 cable.
•
V.35 compliance requires an Order No. 7220 or 7932 cable
•
X.21 compliance requires an Order No. 7224 or 7936 cable.
Table D-4.
Safety Status (Order Nos. CV0004011, CV0004012,
CV0004013, CV0004014, CV0004015, CV0004026,
CV0004027)
Port Location
Port Description
Type of Circuit
COM3, COM4, and COM5,
COM6, COM7, COM8, and
COM9
V.28, X.21, V.35
Telecommunications
network voltage (TNV) at
SELV levels
AUI
Ethernet AUI
SELV
10Base-T
Ethernet 10BASE-T
SELV
MAU
Token Ring
SELV
J2
Host Port
SELV
10/100BASE-T
Ethernet 10/100BASE-T
SELV
JB1
Host Port
SELV