background image

SPLIT SYSTEM AIR CONDITIONER

*SA1BF4M2SN - 24K, 36K, 48K, & 60K (2, 3, 4, & 5 TON) SERIES - SINGLE PHASE MODELS

16 SEER

IMPORTANT

ATTENTION INSTALLERS:

It is your responsibility to know this product better 

than your customer. This includes being able 

to install the product according to strict safety 

guidelines and instructing the customer on how 

to operate and maintain the equipment for the 

life of the product. Safety should always be the 

deciding factor when installing this product and 

using common sense plays an important role as 

well. Pay attention to all safety warnings and any 

other special notes highlighted in the manual. 

Improper installation of the unit or failure to follow 

safety warnings could result in serious injury, 

death, or property damage.
These instructions are primarily intended to assist 

qualified individuals experienced in the proper 

installation of this appliance. Some local codes 

require licensed installation/service personnel for 

this type of equipment. Please read all instructions 

carefully before starting the installation. Return 

these instructions to the customer’s package for 

future reference.

DO NOT DESTROY. PLEASE READ CAREFULLY & 

KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INFORMATION ......................... 2
AIR CONDITIONER INSTALLATION ............................ 3

General Information ...................................................... 3

Before You Install this Unit ............................................ 3

Locating the Air Conditioner .......................................... 3

Packaging Removal ...................................................... 3

Ground Level ................................................................ 3

Roof Mount ................................................................... 3

Connecting Refrigerant Tubing Between the Indoor

& Outdoor Unit .............................................................. 3

ELECTRICAL WIRING .................................................. 4

Pre-Electrical Checklist ................................................. 4

Line Voltage .................................................................. 4

CoreSense

TM

 Diagnostics Module................................. 4

Compressor Protection ................................................ 5

Resetting Alert Codes .................................................. 5

Grounding ..................................................................... 5

Thermostat Connections ............................................... 5

START UP & ADJUSTMENTS ...................................... 6

Pre-Start Check List ...................................................... 6

Start-Up Procedures ..................................................... 6

Air Circulation - Indoor Blower ..................................... 6

System Cooling ............................................................ 6

System Heating (optional) ........................................... 6

AIR CONDITIONER MAINTENANCE ............................ 6

Panel Removal .............................................................. 6

Panel Installation ........................................................... 6

REFRIGERANT CHARGING ......................................... 7

Charging the Unit in AC mode ...................................... 8

If the outdoor temperature is 65 degrees F or higher: . 8

If the outdoor temperature is below 65 degrees F: ...... 8

WIRING DIAGRAMS & TABLES ................................... 9

Figure 6. Wiring Diagram for *SA1BF4M2SN

(2 Ton Units Without CoreSense

TM

) .............. 9

Figure 7. Wiring Diagram for *SA1BF4M2SN

(2 Ton Units With CoreSense

TM

) ................... 10

Figure 8. Wiring Diagram for *SA1BF4M2SN

(3 Ton Units Without CoreSense

TM

) .............. 11

Figure 9. Wiring Diagram for *SA1BF4M2SN

(3 Ton Units With CoreSense

TM

) ................... 12

Figure 10. Wiring Diagram for *SA1BF4M2SN

(4 & 5 Ton Units Without CoreSense

TM

) ..... 13

Figure 11. Wiring Diagram for *SA1BF4M2SN

(4 & 5 Ton Units With CoreSense

TM

) .......... 14

CORESENSE

TM

 TROUBLESHOOTING ........................ 15

Table 1. CoreSense

TM 

LED Diagnostics ....................... 15

INSTALLATION CHECKLIST ........................................ 20
REPLACEMENT PARTS ............................................... 20

Содержание SA1BF4M2SN Series

Страница 1: ...IMPORTANT SAFETY INFORMATION 2 AIR CONDITIONER INSTALLATION 3 General Information 3 Before You Install this Unit 3 Locating the Air Conditioner 3 Packaging Removal 3 Ground Level 3 Roof Mount 3 Connec...

Страница 2: ...nt Refrigerant and electrical line should be routed through suitably waterproofed openings to prevent water from leaking into the structure This unit is designed for outdoor installations only and sho...

Страница 3: ...n 18 inches from the outside walls of the facility and in an area free from overhead obstructions to ensure unrestricted airflow through the outdoor unit Sufficient clearance for unobstructed airflow...

Страница 4: ...for loose connections Line Voltage A wiring diagram is located on the inside cover of the electrical box of the outdoor unit The installer should become familiar with the wiring diagram before making...

Страница 5: ...instructions supplied with the thermostat and the indoor equipment Typical AC and thermostat hookups are shown in Figure 3 The outdoor unit is designed to operate from a 24 VAC Class II control circu...

Страница 6: ...ify that it is warmer than ambient temperature Listen for any unusual noises Ifunusualsoundsoccur determinethesourceofthenoise and correct as necessary AIR CONDITIONER MAINTENANCE WARNING To prevent e...

Страница 7: ...unit Use only gage line sets which have a Schrader depression device present to actuate the valve Ahigh pressureswitchisfactory installedandlocatedinthe liquidlineinternaltotheoutdoorunit Theswitchis...

Страница 8: ...the recommended superheat value in the table then ADD refrigerant For TXV systems If your measured subcooling at the liquid valve is LESS THAN the recommended subcooling value in the table then ADD re...

Страница 9: ...uitable for 105 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace airhandler installation instructions for control circuit and opti...

Страница 10: ...R L2 T2 COMPRESSOR CONTACTS L1 T1 COMPRESSOR OUTDOOR FAN MOTOR Y2 Y L R C P DC SOL CSC C R Y2 Y LPS HPS CORESENSE COMPRESSOR SOLENOID COIL 24 VOLT FIELD CONNECTIONS CC Contactor Coil CCH Crankcase He...

Страница 11: ...0 Hz WIRING DIAGRAM 7110150 1209 FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE BLACK BLUE YELLOW BLUE BLACK 208 230V H C F CCH R C S S C H L2 T2 COMPRESSOR CONTACTS L1 T1 COMPRESSOR FAN MOTOR L FAN REL...

Страница 12: ...e unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace airhandler installation instructions for control circuit and optional relay transformer kits 7 Couper le courant avant de faire...

Страница 13: ...HPS COMPRESSOR SOLENOID COIL 24 VOLT FIELD CONNECTIONS CC 208 230V Two Stage Split System Air Conditioner Outdoor Section With ECM Outdoor Motor Single Phase 60 Hz NOTES 1 Disconnect all power before...

Страница 14: ...rcuit See furnace airhandler installation instructions for control circuit and optional relay transformer kits 7 Couper le courant avant de faire letretien 8 Employez uniquement des conducteurs en cui...

Страница 15: ...m 6 Thermostat is malfunctioning Check thermostat sub base or wiring for short circuit Check thermostat installation location level Yellow ALERT Flash Code 2 Compressor Pressure Trip High Refrigerant...

Страница 16: ...ssor bearings are seized Measure compressor oil level Red LOCKOUT Flash Code 5 Yellow Off Compressor Moderate Run Trip 1 Evaporator blower is not running Check blower relay coil and contacts Check blo...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...allon MO Nortek Global HVAC LLC 2018 All Rights Reserved REPLACEMENT PARTS Replacement parts are available through your distributor Please have the complete model and serial number of the unit when or...

Отзывы: