Table A-6 Direct Drive Blower Set-Up PSC Motor
Blower Set-Up
Cooling Capacity
0.20 in. w.c.
0.50 in. w.c.
Furnace Model
Blower
Speed
Motor
Speed
Motor
Tons
Power
CFM
Range
O4HD-070A-12-FB
O4HD-070A-14-FA-DV
100-10T
DD
Low
1/2 HP Med-Low 1/2 HP
3
1/2 HP 690 – 1500
O4HD-091A-12-FB
O4HD-091A-14-FA-DV
100-10T
DD
Med-Low
1/2 HP Med-High
1/2 HP
3
1/2 HP 690 – 1500
O4HD-105A-12-FB
O4HD-105A-14-FA-DV
100-10T
DD
Med-
High
1/2 HP
High
1/2 HP
3
1/2 HP 690 – 1500
Table A-7 Direct Drive Blower Characteristics PSC Motor
CFM
External Static Pressure – Inches w.c.
Furnace Model
Blower
Motor
HP
Motor
FLA
∆
T
Speed
0.2
0.3
0.4
0.5
0.6
High 1741 1651 1556 1476 1369
O4HD-A-12-FB
O4HD-14-FA-DV
Med-
High
1557 1497 1434 1369 1278
Med-
Low
1063 1051 1037 1037 1011
070-105
100-10T
DD
1/2 HP
7
60°F
Low 697 697 687 672 646
13
Содержание O4HD-091A-12-FB
Страница 34: ...34...