DC Inverter U-match Series Floor Ceiling Type Unit
11
4.2 Outdoor Unit Installation
ķ
. Install the unit where it will not be tilted by more than 5°.
ĸ
. During installation, if the outdoor unit has to be exposed to strong wind, it must be securely
mounted.
4.2.1 Outdoor unit dimension
Fig. 4.6
Table 4.2 Unit: mm (inch)
Item
Model
A B C D E
GXH18(5.3)USV4DH
955(37-5/8)
395(15-1/2)
700(27-1/2)
560(22)
360(14-1/8)
GXH24(7.0)USV4DH
980(38-5/8)
425(16-3/4)
790(31-1/8)
610(24)
395(15-1/2)
GXH30(8.8)USV4DH
GXH36(10.6)USV4DH
1105(43-5/8)
440(17-3/8)
1100(43-1/4)
630(24-7/8)
400(15-3/4)
GXH42(12.3)USV4DH
960(37-3/4)
410(16-1/4)
1350(53-1/8)
570(22-1/2)
375(14-3/4)
GXH48(14.1)USV4DH
4.2.2 Outdoor Unit Condensate Drainage (Heat pump unit
only) (Fig. 4.7)
(1). It is required to install a drain pipe for the outdoor unit to drain condensate
water during heating operation (only for the heat pump unit).
(2). All holes, with the exception of the drain pipe hole, should be plugged so as
to avoid water leakage (for heat pump unit only).
(3). Installation Method: Insert the pipe joint into the
Φ
25mm (1inch) hole