Nortek DS4BF Скачать руководство пользователя страница 2

2

 Warning:

Unless noted otherwise in these instructions, 

only factory authorized parts or accessory 

kits may be used with this product. improper 

installation, service, adjustment, or maintenance 

may cause explosion, fire, electrical shock or 

other hazardous conditions which may result in 

personal injury or property damage

 Warning:

the information listed below and the next page 

must be followed during the installation, service, 

and operation of this furnace. Failure to follow 

safety recommendations could result in possible 

damage to the equipment, serious personal 

injury or death.

•  The  installer  must  comply  with  all  local  codes  and 

regulations which govern the installation of this type 

of equipment. Local codes and regulations take 

precedence over any recommendations contained in 

these instructions. Consult local building codes and 

the National Electrical Code (ANSI CI) for special 

installation requirements.

•  All electrical wiring must be completed in accordance 

with local, state and national codes and regulations 

and with the National Electric Code (ANSI/NFPA 70) 

or in Canada the Canadian Electric Code Part 1 CSA 

C.22.1.

•  This equipment contains liquid and gaseous refrigerant 

under high pressure. DO NOT USE ANY PORTION OF 

THE CHARGE FOR PURGING OR LEAK TESTING.

Installation or servicing should only be performed by 

qualified trained personnel thoroughly familiar with this 

type equipment.

•  Fully annealed, refrigerant grade copper tubing should 

be used when installing the system. Refrigerant suction 

line tubing should be fully insulated.

•  Installation  of  equipment  may  require  brazing 

operations. Installer must comply with safety codes 

and wear appropriate safety equipment (safety glasses, 

work gloves, fire extinguisher, etc.) when performing 

brazing operations.

•  Follow all precautions in the literature, on tags, and 

on labels provided with the equipment. Read and 

thoroughly understand the instructions provided with 

the equipment prior to performing the installation and 

operational checkout of the equipment.

•  Refrigerant and electrical line should be routed through 

suitably waterproofed openings to prevent water from 

leaking into the structure.

important SaFety inFormation

INSTALLER: Please read all instructions before servicing 

this equipment. Pay attention to all safety warnings and 

any other special notes highlighted in the manual. Safety 

markings are used frequently throughout this manual to 

designate a degree or level of seriousness and should 

not be ignored.

Warning  indicates  a  potentially  hazardous  situation 

that if not avoided, could result in personal injury or death.

caUtion indicates a potentially hazardous situation that 

if not avoided, may result in minor or moderate injury or 

property damage.

 Warning:

electrical ShocK, Fire or 

eXploSion haZard

Failure to follow safety warnings exactly could 

result in serious injury or property damage.

improper servicing could result in dangerous 

operation, serious injury, death or property 

damage.
•  Before servicing, disconnect all electrical power 

to the equipment.

•  When servicing controls, label all wires prior 

to disconnecting. reconnect wires correctly.

•  Verify proper operation after servicing.

 Warning:

this split system air conditioner is shipped 

charged with r410a refrigerant and ready 

for installation. if repairs make it necessary 

for evacuation and charging, it should only 

be attempted by qualified trained personnel 

thoroughly familiar with this equipment. Under 

no circumstances should the owner attempt to 

install and/or service this equipment. Failure to 

comply with this warning could result in property 

damage, personal injury, or death.

 caUtion:

this unit uses r-410a refrigerant. do not use 

any other refrigerant in this unit. Use of another 

refrigerant will damage the unit.

Содержание DS4BF

Страница 1: ...ckage for future reference DO NOT DESTROY PLEASE READ CAREFULLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE Installation Instructions important SAFETY INFORMATION 2 Air conditioner INSTallATION 3 Genera...

Страница 2: ...tions in the literature on tags and on labels provided with the equipment Read and thoroughly understand the instructions provided with the equipment prior to performing the installation and operation...

Страница 3: ...g the unit Locating the Air Conditioner Survey the job site to determine the best location for mounting the outdoor unit The outdoor unit should be installed no closer than 18 inches from the outside...

Страница 4: ...of the National Electric Code ANSI NFPA 70 For Canadian installations the electrical connections and grounding shall comply with the current Canadian Electrical Code CSA C22 1 and or local codes Pre E...

Страница 5: ...is also imprinted on the side of the module to quickly direct the technician to the root cause of a problem Alert identification codes are also listed in Table 3 page 15 Compressor Protection TheCoreS...

Страница 6: ...e fan and compressor cycle off with the thermostat NOTE The blower should also stop unless fan mode is set to the ON position System Heating optional 1 Set the thermostat s system mode to HEAT and the...

Страница 7: ...ded Deviationsfromratedairflowsor non listedcombinationsmayrequiremodificationtothe expansion device and refrigerant charging procedures for proper and efficient system operation The refrigerant charg...

Страница 8: ...abel Charging charts are valid for a variety of indoor return air conditions and are most influenced by the outdoor ambienttemperature outdoorfanoperationandtheunit operatingvoltage Beforeusingthesech...

Страница 9: ...onductors suitable for 105 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace airhandler installation instructions for control circu...

Страница 10: ...R C S S C R L2 T2 COMPRESSOR CONTACTS L1 T1 COMPRESSOR OUTDOOR FAN MOTOR Y2 Y L R C P DC SOL CSC C R Y2 Y LPS HPS CORESENSE COMPRESSOR SOLENOID COIL 24 VOLT FIELD CONNECTIONS CC Contactor Coil CCH Cr...

Страница 11: ...le Phase 60 Hz WIRING DIAGRAM 7110150 1209 FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE BLACK BLUE YELLOW BLUE BLACK 208 230V H C F CCH R C S S C H L2 T2 COMPRESSOR CONTACTS L1 T1 COMPRESSOR FAN MOTOR...

Страница 12: ...tection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace airhandler installation instructions for control circuit and optional relay transformer kits 7 Couper le courant avan...

Страница 13: ...ACTS L1 T1 COMPRESSOR CSC C Y2 Y LPS HPS COMPRESSOR SOLENOID COIL 24 VOLT FIELD CONNECTIONS CC 208 230V Two Stage Split System Air Conditioner Outdoor Section With ECM Outdoor Motor Single Phase 60 Hz...

Страница 14: ...class 2 circuit See furnace airhandler installation instructions for control circuit and optional relay transformer kits 7 Couper le courant avant de faire letretien 8 Employez uniquement des conducte...

Страница 15: ...functioning Check thermostat sub base or wiring for short circuit Check thermostat installation location level Yellow ALERT Flash Code 2 Compressor Pressure Trip High Refrigerant Charge Discharge pres...

Страница 16: ...seized Measure compressor oil level Red LOCKOUT Flash Code 5 Yellow Off Compressor Moderate Run Trip 1 Evaporator blower is not running Check blower relay coil and contacts Check blower motor capacito...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...______________________ Unit Installed Minimum clearances per Figure 1 page 3 YES NO INSTALLER NAME CITY________________________ STATE_________________ REFRIGERATION SYSTEM Was unit given 24 hr warm up...