Nortek DS4BF Скачать руководство пользователя страница 12

12

YELLO

W/

BLA

CK

Y2

Y

L

R

C

P

DC

SOL

CORESENSE

 MODULE

Y2

RC

Y

L1

L2

T1

T2

CONT

AC

TO

R

HIGH PRESSUR

E

SWITCH

LO

W PRESSURE

SWITCH

OUTDOOR

FAN MO

TO

R

COMPRESSOR

TO

 THERMOST

AT

YELLO

W/

BLA

CK

YELLO

W

YELLO

W

GRN

DL

1

L2

SINGLE PHASE

FIELD SUPP

LY

GR

OUNDING

SCREW

BLUE

YELLO

W

BLA

CK

BLA

CK

BLA

CK

RED

ORANGE

C

S

R

CCH

HC

F

L

S

C

RED

BLA

CK

H

COM

NO

FA

N

RELA

Y

NC

LFT

RT

R

OUTE 

THIS 

WIRE 

THR

OUGH 

“C

” OPENING

IN CORESENSE MODULE

R

OUTHE 

THIS 

WIRE 

THR

OUGH 

“S”

OPENING IN CORESENSE MODULE

CAP

A

CIT

OR

BLA

CK

BLA

CK

R

OUTE 

THIS 

WIRE 

THR

OUGH 

“R”

OPENING IN CORESENSE MODULE

YELLO

W

CC- Contactor Coil

CCH - Crankcase Heater

LPS - Lo

w Pressure Switch

HPS - High Pressure Switch

CSC - Compressor Solenoid Coi

l

OFR - Outdoor F

an Rela

y Coil

Y2

Y

L

R

C

P

DC

SOL

CS

C

C R

Y2

Y

LPS

HPS

CORESENSE

COMPRESSOR

SOLENOID COIL

24 

VO

LT

 FIELD

CONNECTIONS

208/230V

Tw

o Stage Split Air Conditioner (Outdoor Section)

With 

Tw

o Speed Outdoor F

an Motor

Single Phase / 60 Hz.

10/13

FIELD 

WIRIN

G

LEGEND

:

LO

VO

LT

AG

E

HIGH 

VO

LT

AG

E

YELLOW

BLACK

RED

BLUE

YELLO

W

BLUE

GRA

Y

208/230V

H

C

F

CCH

R

C

S

S

C

H

L2

T2

COMPRESSOR

CONT

AC

TS

L1

T1

COMPRESSOR

FA

N MO

TO

R

L

FA

N REL

AY

CC

OF

R

NO

TES:

1.

 Disconnect all po

wer bef

ore servicing.

2.

 For suppl

y connections use copper conductor

s on

ly

.

3.

 Not suitable on systems that e

xceed 150 v

olts to gr

ound.

4.

 For replacement wires use conductor

s suitable f

or 10

5

5.

 For ampacities and o

ver

current pr

otection

, see unit rating plat

e.

6.

 Connect to 24 v

ac/40v

a/c

lass 2 cir

cuit.

 See furnace/airhandler installation

     instructions f

or contr

ol cir

cuit and optional rela

y/transf

ormer kits.

7.

 Couper le courant 

av

ant de faire letretien.

8.

 Empl

oy

ez uniquement des conducteur

s en cuivre

.

9.

 Ne con

vient pas aux installations de plus de 150 v

olt a la terr

e.

CA

PA

CI

TO

R

WIRING DIA

GRAM

Nor

mal Operation, no tr

ip

Status LE

D

Nor

mal Run

; Solid Green

N/

AN

/A

N/

A

N/

A

N/

A

N/

A

N/

A

4 cons

, 10x total

4 cons

, 10x total

4 con

s,

 10x tota

l

1 Occurrence

1 Occurrence

1 Occurrence

10 consecutiv

e

R

ed:

 Flash 

2

R

ed:

 Flash 

3

R

ed:

 Flash 

4

R

ed:

 Flash 

5

R

ed:

 Flash 

6

R

ed:

 Flash 

7

R

ed:

 Flash 10

N/

A

Code 1;

 Y

ello

w Flash 

1

Code 2;

 Y

ello

w Flash 

2

Code 3;

 Y

ello

w Flash 

3

Code 4;

 Y

ello

w Flash 

4

Long Run 

Time

.  Compressor r

unning e

xtremely long 

ru

n cycl

e.

  (disab

led in HP mod

e.

)

noi

ta

ci

dnI

 t

uo

kc

oL

le

ve

L t

uo

kc

oL

noi

tpi

rc

se

D

EL 

sut

at

S

Compr

sesor Pressure 

Trip.

  Disch.

 or suct.

 pressure out of limits or compressor 

ov

er

loaded.

Shor

t Cyc

ling.

  Compressor is r

unning only br

iefly

.

Loc

ked Rotor

.

Code 5;

 Y

ello

w Flash 

5

Compressor Moderate Run.

  Compressor r

uns >15min, then tr

ips >7min.

Code 6;

 Red Flash 

6

Open Star

t Cir

cuit.

  Current only in r

un circuit.

Code 7;

 Red Flash 

7

Open Sta

rt

 Cir

cuit.

  Current only in sta

rt

 circuit.

Code 8;

 Y

ello

w Flash 

8

W

elded Contactor

.  Compressor alw

ays r

uns

.

Code 9;

 Y

ello

w Flash 

9

Lo

Voltage

.  Control circuit <17 

VA

C.

Code 10;

 Red Flash 10

Over Current Pr

otection

.  PR

OT

 ter

minal has >2A input f

or more than 40ms

711208

0

Figure 8. W.d. for 3 ton models with coreSense

tm 

Содержание DS4BF

Страница 1: ...ckage for future reference DO NOT DESTROY PLEASE READ CAREFULLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE Installation Instructions important SAFETY INFORMATION 2 Air conditioner INSTallATION 3 Genera...

Страница 2: ...tions in the literature on tags and on labels provided with the equipment Read and thoroughly understand the instructions provided with the equipment prior to performing the installation and operation...

Страница 3: ...g the unit Locating the Air Conditioner Survey the job site to determine the best location for mounting the outdoor unit The outdoor unit should be installed no closer than 18 inches from the outside...

Страница 4: ...of the National Electric Code ANSI NFPA 70 For Canadian installations the electrical connections and grounding shall comply with the current Canadian Electrical Code CSA C22 1 and or local codes Pre E...

Страница 5: ...is also imprinted on the side of the module to quickly direct the technician to the root cause of a problem Alert identification codes are also listed in Table 3 page 15 Compressor Protection TheCoreS...

Страница 6: ...e fan and compressor cycle off with the thermostat NOTE The blower should also stop unless fan mode is set to the ON position System Heating optional 1 Set the thermostat s system mode to HEAT and the...

Страница 7: ...ded Deviationsfromratedairflowsor non listedcombinationsmayrequiremodificationtothe expansion device and refrigerant charging procedures for proper and efficient system operation The refrigerant charg...

Страница 8: ...abel Charging charts are valid for a variety of indoor return air conditions and are most influenced by the outdoor ambienttemperature outdoorfanoperationandtheunit operatingvoltage Beforeusingthesech...

Страница 9: ...onductors suitable for 105 5 For ampacities and overcurrent protection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace airhandler installation instructions for control circu...

Страница 10: ...R C S S C R L2 T2 COMPRESSOR CONTACTS L1 T1 COMPRESSOR OUTDOOR FAN MOTOR Y2 Y L R C P DC SOL CSC C R Y2 Y LPS HPS CORESENSE COMPRESSOR SOLENOID COIL 24 VOLT FIELD CONNECTIONS CC Contactor Coil CCH Cr...

Страница 11: ...le Phase 60 Hz WIRING DIAGRAM 7110150 1209 FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE BLACK BLUE YELLOW BLUE BLACK 208 230V H C F CCH R C S S C H L2 T2 COMPRESSOR CONTACTS L1 T1 COMPRESSOR FAN MOTOR...

Страница 12: ...tection see unit rating plate 6 Connect to 24 vac 40va class 2 circuit See furnace airhandler installation instructions for control circuit and optional relay transformer kits 7 Couper le courant avan...

Страница 13: ...ACTS L1 T1 COMPRESSOR CSC C Y2 Y LPS HPS COMPRESSOR SOLENOID COIL 24 VOLT FIELD CONNECTIONS CC 208 230V Two Stage Split System Air Conditioner Outdoor Section With ECM Outdoor Motor Single Phase 60 Hz...

Страница 14: ...class 2 circuit See furnace airhandler installation instructions for control circuit and optional relay transformer kits 7 Couper le courant avant de faire letretien 8 Employez uniquement des conducte...

Страница 15: ...functioning Check thermostat sub base or wiring for short circuit Check thermostat installation location level Yellow ALERT Flash Code 2 Compressor Pressure Trip High Refrigerant Charge Discharge pres...

Страница 16: ...seized Measure compressor oil level Red LOCKOUT Flash Code 5 Yellow Off Compressor Moderate Run Trip 1 Evaporator blower is not running Check blower relay coil and contacts Check blower motor capacito...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...______________________ Unit Installed Minimum clearances per Figure 1 page 3 YES NO INSTALLER NAME CITY________________________ STATE_________________ REFRIGERATION SYSTEM Was unit given 24 hr warm up...

Отзывы: