INSTALLER: PLEASE LEAVE THESE  

INSTALLATION INSTRUCTIONS WITH 

THE HOMEOWNER

7087060 

(Replaces  7086340)  

the drain pan and cause a condensate 
leak.

2.  Connect the drain line and run to a suitable 

drain avoiding sharp bends and pinching of 

the line. Install a condensate trap and prime 
with water.

3.  During  the  system  checkout,  inspect  the 

drain line and connections to verify proper 
condensate disposal.

Air Filter —

 Air filters are not provided as an 

integral part of this coil, however, a filter must 

be installed upstream of the coil and inspected 

frequently. When the filter becomes clogged with 

dust or lint, it should be replaced (disposable type) 

or cleaned (washable type). The filter should be 
inspected and replaced or cleaned at least twice 

during the year, generally at the start of each 
heating and cooling season.
 

Close-Off Plates and Panels — 

Install  the 

necessary air close-off plates around the 

refrigerant lines and drain line where required. 

Reinstall all inner and outer panels of the coil 

case and furnace that were previously removed 

to install the indoor coil.

Refrigerant Charging — 

These cased indoor 

coils are not factory charged with refrigerant.

It will be necessary to evacuate the indoor coil 

and line set prior to charging. Refer to the outdoor 
unit installation manual for detailed charges and 
instructions.

7. MAINTENANCE AND SERVICE

 WARNING:

Ensure that all electrical power to the 
furnace and outdoor (condensing) 
unit is off before performing any 
maintenance or service on the 

system.

To ensure optimum performance and to minimize 
possible equipment failure, the following periodic 

maintenance should be performed on this 

equipment:

1.   The air filter installed with the system should 

be checked and cleaned or replaced twice 

per year.

2.   Check the coil, drain pan, and condensate 

drain line for cleanliness at the start of 

each  heating  and  cooling  season.  Clean 

as needed.

 CAUTION:

Do not operate the system without 
having a suitable filter in place in 
the return air duct system. Always 
replace the filter with the same size 
and type.

Specifications & illustrations subject to change 
without notice or incurring obligations (05/15).
O’Fallon, MO, © Nortek Global HVAC LLC 2015. 
All Rights Reserved.

Содержание C5B

Страница 1: ...tionsand orfurnace air handler markings before proceeding with installation of the coil These instructions are primarily intended to assist qualified individuals experienced in the proper installation...

Страница 2: ...izontal Furnace Horizontal Ready Coils for Horizontal Left Installation Horizontal Ready Coils for Horizontal Right Installation 4 Verify Pressurization 6 5 Refrigerant Line Connections 6 6 Completing...

Страница 3: ...tdoor unit NOTE Some coils employ a thermostatic expansion valve TXV as the metering device See page 4 H 20 3 4 B 16 5 8 W A 3 4 133 8 155 8 19 3 4 Figure 1 3 Wherepreciseformingoftherefrigerantlines...

Страница 4: ...63 913963 913963 913964 913964 913964 Extra Orifice in N A 0 053 for 1 5 ton condenser N A N A 0 053 for 1 5 ton condenser N A N A N A N A N A N A N A N A Coil Model 1 C5BA H T X24C A C5BA H T25C A C5...

Страница 5: ...the threaded holes of the horizontal drain pan If webbing is not removed the drain will not function properly and ceiling damage may occur 3 Insert a plug from the horizontal drain pan into the open a...

Страница 6: ...id direct face exposure or contact with valve when gas is escaping Always ensure adequate ventilation ispresentduringthedepressurization process Any uncertainties should be addressed before proceeding...

Страница 7: ...ends of the lines must be round clean and free of any burrs 13 Place grommets in proper orientation onto line set with sufficient distance to braze joint 14 Insert the line set tubes into the coil tub...

Страница 8: ...coil case and furnace that were previously removed to install the indoor coil Refrigerant Charging These cased indoor coils are not factory charged with refrigerant It will be necessary to evacuate th...

Отзывы: