background image

4

2.

 COIL SPECIFICA

TIONS

(1

Ref

er

 to

 sales

 specification

 sheets

 f

or

 Listed/Cer

tified

 combinations

 of

 

 

equipment and required accessor

ies

.

(2)

  

Ref

er

 to

 the

 current

 ARI

 Director

for

 cer

tified

 r

atings

 of

 split

 systems

.

(3) 

Or

ifice

 siz

is

 for

 13

 SEER

 R-22

 systems

. Additional

 or

ifices

 ma

be

 supplied

 

with

 the

 condenser

.

(4) 

Allo

ws

 application

 of

 larger

 coil

 cases

 to

 smaller

 fur

nace

 cabinet.

(5

X

 in

 the

 model

 descr

iption

 designates

 factor

installed

 TXV

 for

 R-410A

 refr

iger

ant.

(6)

 

T in the model descr

iption designates f

actor

y installed 

TXV f

or R-22 refr

iger

ant.

(7)

   

Not

 required

 for

 "H"

 hor

iz

ontal

 ready

 coils

.

Coil Model (1)

C5B

A/H 

024C-A

C5B

A/H 

025C-A

C5B

A/H 

030C-A

C5B

A/H 

024C-B

C5B

A/H 

025C-B

C5B

A/H 

030C-B

C5B

A/H 

036C-B

C5B

A/H 

037C-B

C5B

A/H 

042C-B

C5B

A/H 

048C-B

C5B

A/H 

048C-C

C5B

A/H 

049C-C

C5B

A/H 

060C-C

Nominal Capacity BTUH (2)

24,000

24,000

30,000

24,000

24,000

30,000

36,000

36,000

42,000

48,000

48,000

48,000

60,000

Nominal Airflo

w CFM

800

800

1000

800

800

1000

1200

1200

1400

1600

1600

1600

2000

Width 

(in.) W

14 1/4

14 1/4

14 1/4

19 3/4

19 3/4

19 3/4

19 3/4

19 3/4

19 3/4

19 3/4

22 1/2

22 1/2

22 1/2

Height (in.) H (std/horz)

20/26

20/26

20/26

20/26

20/26

20/26

20/26

26/26

26/26

26/26

26/26

29/29

29/29

Top (in.) A

12 7/8

12 7/8

12 7/8

18 3/8

18 3/8

18 3/8

18 3/8

18 3/8

18 3/8

18 3/8

21 1/8

21 1/8

21 1/8

Connections            Liquid Li Line

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

                                   Suction Line

3/4

3/4

3/4

3/4

3/4

3/4

3/4

7/8

7/8

7/8

7/8

7/8

7/8

Installed Orifice Siz

e (in.) (3)

0.050

0.060

0.065

0.050

0.060

0.065

0.075

0.075

0.078

0.089

0.089

0.089

0.099

Horizontal Drain Kit (7)

919318

919318

919318

919318

919318

919318

919318

919319

919319

919319

919319

919320

919320

Coil Case Adapter (4)

-

-

-

913963

913963

913963

913963

913963

913963

913963

913964

913964

913964

Extra Orifice (in.)

N/A

0.053 f

or 

1.5-ton 

condenser

N/A

N/A

0.053 f

or 

1.5-ton 

condenser

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Coil Model (1)

C5B

A/H 

T/X24C-A

C5B

A/H 

T25C-A

C5B

A/H 

T/X30C-A

C5B

A/H 

T/X24C-B

C5B

A/H 

T25C-B

C5B

A/H 

T/X30C-B

C5B

A/H 

T/X36C-B

C5B

A/H 

T37C-B

C5B

A/H 

T/X42C-B

C5B

A/H 

T/X48C-B

C5B

A/H 

T/X48C-C

C5B

A/H 

T/X49C-C

C5B

A/H 

T/X60C-C

Nominal Capacity BTUH (2)

24,000

24,000

30,000

24,000

24,000

30,000

36,000

36,000

42,000

48,000

48,000

48,000

60,000

Nominal Airflo

w CFM

800

800

1000

800

800

1000

1200

1200

1400

1600

1600

1600

2000

Width 

(in.) W

14 1/4

14 1/4

14 1/4

19 3/4

19 3/4

19 3/4

19 3/4

19 3/4

19 3/4

19 3/4

22 1/2

22 1/2

22 1/2

Height (in.) H (std/horz)

20/26

20/26

20/26

20/26

20/26

20/26

20/26

26/26

26/26

26/26

26/26

29/29

29/29

Top (in.) A

12 7/8

12 7/8

12 7/8

18 3/8

18 3/8

18 3/8

18 3/8

18 3/8

18 3/8

18 3/8

21 1/8

21 1/8

21 1/8

Connections               Liquid Line

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

                                   Suction Line

3/4

3/4

3/4

3/4

3/4

3/4

3/4

7/8

7/8

7/8

7/8

7/8

7/8

Metering De

vice

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

Horizontal Drain Kit (7)

919318

919318

919318

919318

919318

919318

919318

919319

919319

919319

919319

919320

919320

Coil Case Adapter (4)

-

-

-

913963

913963

913963

913963

913963

913963

913963

913964

913964

913964

Coil Model (1) (5)

C4B

X24C-B

C4BH 

X24C-B

C4B

X36C-B

C4BH 

X36C-B

C4B

X48C-C

C4BH 

X48C-C

C4B

X60C-C

C4BH 

X60C-C

Nominal Capacity BTUH (2)

24,000

24,000

36,000

36,000

48,000

48,000

60,000

60,000

Nominal Airflo

w CFM

800

800

1200

1200

1600

1600

2000

2000

Width 

(in.) W

19 3/4

19 3/4

19 3/4

19 3/4

22 1/2

22 1/2

22 1/2

22 1/2

Height (in.) H

20

26

26

26

29

29

29

29

Top (in.) A

18 3/8

18 3/8

18 3/8

18 3/8

21 1/8

21 1/8

21 1/8

21 1/8

Connections               Liquid Line

3/8

3/8

3/8

3/8

3/8

3/8

3/8

3/8

                                  Suction Line

3/4

3/4

7/8

7/8

7/8

7/8

7/8

7/8

Metering De

vice

TXV

TXV

TXV

TXV

TXV

TXV

TXV

TXV

Horizontal Drain Kit (7)

919318

-

919319

-

919320

-

919320

-

Содержание C5B

Страница 1: ...tionsand orfurnace air handler markings before proceeding with installation of the coil These instructions are primarily intended to assist qualified individuals experienced in the proper installation...

Страница 2: ...izontal Furnace Horizontal Ready Coils for Horizontal Left Installation Horizontal Ready Coils for Horizontal Right Installation 4 Verify Pressurization 6 5 Refrigerant Line Connections 6 6 Completing...

Страница 3: ...tdoor unit NOTE Some coils employ a thermostatic expansion valve TXV as the metering device See page 4 H 20 3 4 B 16 5 8 W A 3 4 133 8 155 8 19 3 4 Figure 1 3 Wherepreciseformingoftherefrigerantlines...

Страница 4: ...63 913963 913963 913964 913964 913964 Extra Orifice in N A 0 053 for 1 5 ton condenser N A N A 0 053 for 1 5 ton condenser N A N A N A N A N A N A N A N A Coil Model 1 C5BA H T X24C A C5BA H T25C A C5...

Страница 5: ...the threaded holes of the horizontal drain pan If webbing is not removed the drain will not function properly and ceiling damage may occur 3 Insert a plug from the horizontal drain pan into the open a...

Страница 6: ...id direct face exposure or contact with valve when gas is escaping Always ensure adequate ventilation ispresentduringthedepressurization process Any uncertainties should be addressed before proceeding...

Страница 7: ...ends of the lines must be round clean and free of any burrs 13 Place grommets in proper orientation onto line set with sufficient distance to braze joint 14 Insert the line set tubes into the coil tub...

Страница 8: ...coil case and furnace that were previously removed to install the indoor coil Refrigerant Charging These cased indoor coils are not factory charged with refrigerant It will be necessary to evacuate th...

Отзывы: