9 Malfunction Analysis 

WARNING

 

Do not repair the air conditioner by yourself. Faulty repair could lead to electric shock or fire. Please contact a 
qualified technician to have the unit. Check the following items before contacting the service center, as it could 
save you time and expense. 

 

Malfunction Phenomena 

Malfunction Analyzing 

The air conditioner could not start up 
just after turned off 

The over load protection switch requires a 3 minute delay before unit will 
run again 

Unit emits an odor after just turning 
on. 

Odors or cigarette smoke which has been absorbed is discharged.  

Slight clicking was heard when the 
unit was running 

This is the sound of the running refrigerant 

Mist came from the air outlet vent 
when cooling 

Indoor air is cooled rapidly 

Creaking sound was heard when the 
unit was running or after it was 
turned off 

It is the normal sound of the panel and other parts expanding or 
contracting due to temperature change. 

The air conditioner failed to run 

Is the power supply cut off? 
Is the power supply connected? 
Is the circuit breaker properly set? 
Is the voltage too high or too low   
Is the TIMER set on the wireless remote controller? 

Poor cooling (heating) effect   

Is the thermostat set properly? 
Is the inlet, outlet vent of the outdoor unit blocked? 
Is the air filter too dirty to cause blockage? 
Are windows and doors closed? Is the air speed too low?  
Is there other heat source in the room? 

The wireless remote controller 

won’t

 

work 

In the event that the battery is replaced but the wireless remote control 
still malfunctions, then open the back cover and press 

”ACL” button to 

reset it. 
When the air conditioner functions are changed too frequently, the 
wireless remote controller may malfunction. To resume the normal 
operation de-energize and then re-energize the wireless controller. 
Is the controller close enough to the air conditioner to receive the signal? 
Is there an obstacle blocking the signal? Do the batteries need 
replacing? 

 

9.1 When to contact a service technician 

When the following conditions occur, please stop operating immediately, cut off the main 

power supply of the unit and then contact the service. 

  Harsh sound heard when running;   

  The fuse or circuit breaker trips frequently; 

  Substance or water pulled in the unit involuntarily; 

Содержание B-HW-2.2(07)-A3AK

Страница 1: ...y before operation and retain it for future reference Specifications illustrations subject to change without notice or incurring obligations Multi Variable Heat Pump Wall Mounted Type Indoor Unit Mode...

Страница 2: ...l capacity of outdoor units otherwise poor cooling or heating performance may result 5 Direct operators or maintainers should keep this manual for future reference 6 If this unit fails to operate norm...

Страница 3: ...nnect Cables and Terminals of Wiring Board 9 5 2 Power Cord Connection 9 5 3 Connection of Communication Line of IDU and ODU 10 5 4 Connection of Communication Line of Wired Controller 10 5 5 Illumina...

Страница 4: ...when gas oil heating equipment is used 10 Never start up or shut off the air conditioner by plugging or unplugging the power cord 11 Let the unit run for at least five minutes after startup otherwise...

Страница 5: ...t thinner or gasoline will damage the unit appearance Only use soft cloth with a little mild detergent to clean the outer casing of unit 26 If anything abnormal occurs such as burning smell please pow...

Страница 6: ...tioners No Part Name No Part Name Surface panel Guide louver Filter Drain pipe Wiring cover 2 2 Rated Operating Condition Item Indoor Side Condition Outdoor Side Condition Dry Bulb Temp C F Wet Bulb T...

Страница 7: ...stalled at another location 4 The appliance shall not be installed in a laundry room 5 The indoor unit should be installed at least 2 3m 7 5 ft above the floor 3 2 Requirements for Communication Line...

Страница 8: ...s shall be twisted together 3 If unit is installed in or near strong electromagnetic field use shielded wire 3 3 Electric Installation Model Power Supply MCA A MOP A B HW 2 2 07 A3AK 208 230V 1ph 60Hz...

Страница 9: ...he installation of the rear panel Fig 4 2 1 Use a level to hang the rear panel Since the drainage pipe is on the left side it is necessary to adjust the rear panel to make its left side a little bit l...

Страница 10: ...in 5 seconds press button and then press button three times After finishing setting UC is displayed on receiver light board for 5 seconds and MASTER icon is displayed on wired controller 4 3 2 Setting...

Страница 11: ...e connection pipe with two leading pipes and then tighten the joint nuts Connect the connect pipe with the two relative leading pipe tie the nut on tie in of the connect pipe tightly Notes Be careful...

Страница 12: ...ion wire between indoor unit and outdoor unit 8 Adjust the static pressure via wired controller as needed 5 1 Connect Cables and Terminals of Wiring Board Connection of Wire and Patch Board Terminal 1...

Страница 13: ...f indoor unit as shown in Fig 5 3 1 Fig 5 3 1 Fig 5 3 2 4 Secure the communication line to the electric box with the wire 5 In order to ensure the reliability of communication between IDU and ODU and...

Страница 14: ...address settings Address 1 is for main controller Address 2 is for slave controller Detailed setting please refer to the instruction manual of wired controller 5 6 Installation of the indoor unit 1 Wh...

Страница 15: ...door temperature 2 For more efficient heating affect adjust the louvers downward For better cooling affect adjust the louvers more horizontal 3 When the air conditioner is running don t leave windows...

Страница 16: ...rrows to take down the panel 2 Clean the panel Clean it with a soft hair brush water and mild detergent and then dry it 3 Reinstall the panel As shown in Fig II install the stands of both ends of the...

Страница 17: ...he inlet or outlet vent of the air conditioner is blocked 2 Check if the ground wire is securely attached 3 Check if the batteries in the wireless remote controller need replacing 4 Check if the air f...

Страница 18: ...it Network Address Error L3 Water Full Protection LC Outdoor Indoor Incompatibility Error dH Wired Controller Circuit Board Error L4 Wired Controller Power Supply Error d1 Indoor Unit Circuit Board Er...

Страница 19: ...Is the power supply connected Is the circuit breaker properly set Is the voltage too high or too low Is the TIMER set on the wireless remote controller Poor cooling heating effect Is the thermostat s...

Страница 20: ...1 The wireless remote controller can make the guide louver swing up and down or makes the guide louver stop at a certain 2 Press the SWING button on the wireless remote controller to make the guide l...

Страница 21: ...Specifications illustrations subject to change without notice or incurring obligations O Fallon MO 12 15 Nortek Global HVAC LLC 2015 All Rights Reserved 550E 1215...

Отзывы: