ALL output
voltages are
Class 2
Terminal 1 only
provides power when
the Control Panel’s
power supply is
connected to an
AC power source.
CONTROL PANEL
1 – 14VDC Power Input (+)
2 – 14VDC Power Input (–)
3 – Common (GND)
4 – Bell (+)
5 – Bell (–)
6 – Hardwire Zone
OBSERVE POLARITY
when connecting the
Power Supply.
End-of-Line Resistors are
optional on hardwired
loop.
Piezo/Siren
Supervised
Bell Output
14 VDC
@ 500 mA
Maximum
Plug-in
14 VDC 1.7A
Switching
power
supply
2.2 K
Normally Closed
Contact
UL NOTE: Wiring for
all wired sensors
and annunciators
must use UL Listed
low voltage Class 2
or better grade wire.
Sensor and display
voltages must comply
with Class 2 low
voltage requirements
1
2
3
4
5
6
GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved.
16
2GIG is a registered trademark of Nortek Security & Control LLC.
Figure 10
Control Panel Wiring Diagram
Installation
Control Panel Wiring Diagram
The following diagram shows you the Control Panel wiring .