GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved.
31
2GIG is a registered trademark of Nortek Security & Control LLC.
Q#
Programming Question/Sub-Question
Default Setting
Q78 Select Output (00-12)
(11) Follows Internal Sounder Alarm‡
Q79 Select Z-Wave Feature (0 to 3)
(3) Enabled with Local Rules
Q80 Select Z-Wave Switches Feature (0 to 1)
(1) Enabled
Q81 Select Z-Wave Thermostats Feature (0 to 1)
(1) Enabled
Q82 Select Z-Wave Door Locks Feature (0 to 1)
(1) Enabled
Q83 Select Temperature Display Units (0 to 1)
(0) Degrees Fahrenheit
Select date and time format (0 to 2)
(0) MM-DD-YY H:MM AM/PM
Select monetary symbol (0 to 8)
(0) $
Q84 Select Services Require Master Code
(0) Disabled
Q85 Select Master User Access to Z-Wave Toolbox (0 to 1)
(0) Disabled
Q86 Select Disable Siren After Two-Way Audio (0 to 1)
(0) Disabled
Q87 Select Keyfob/Remote Arming Mode on System Not Ready (0 to 2)
(0) Auto-Bypass with Zone Participation
Q88 Select Z-Wave Siren Mode (0 to 1)
(0) Sound for Burglary and Fire/CO
Q89 Select Allow Backlight Always On (Demo Mode)
(0) Disabled
Q90 Select Energy Feature (0 to 2)
(0) Disabled and Hidden
Q91 Select Radio Modem Supplier
Varies by Supplier**
Q92 Select Network Device (0 to 1)
(0) none
Network Device ID (Read-Only)
0
NOTE:
Only appears if (1) Go!Bridge is selected in Q92 Select Network
Device (0 to 1)
Select Configuration Source (0 to 1)
(0) DHCP
If (0) DHCP is selected in Select Configuration Source (0 to 1), the
following sub-questions appear:
Select Port # (1 to 8)
(1) Port 1
NOTE:
This option is automatically selected if you choose (0) DHCP in the
previous question. Typically, you will skip this question unless additional
programming is required.
Select Used (0 to 1)
(0) Disabled
NOTE:
Typically, you will skip this question unless additional
programming is required.
Enter Port Value (0-65535)
0
NOTE:
Only appears if (1) Enabled is selected in Select Used (0 to1)
Enter Port Forward IP Address
000.000.000.000
NOTE:
Only appears if (1) Enabled is selected in Select Used (0 to 1).
NOTE:
Typically, you will accept the default IP address value that
appears.
If (1) Static is selected in Select Configuration Source (0 to 1), the
following sub-questions appear
Enter Device IP Address
Enter Gateway IP Address
Enter Subnet Mask
Q93 Enter Broadband Network Failure Time (1-255)
30
Q94 Select Broadband Network Failure Causes Trouble (0 to 1)
(1) Enabled
Q95 Select Broadband Network Failure Reports (0 to 1)
(1) Enabled
Q96 Select send report 3 times on panel tamper (0 to 1)
(1) Enabled**
Q97 Select sound on normal closing acknowledgment (0 - to - 1)
(1) Enabled**
‡ Indicates the default setting for ANSI/SIA CP-01 compliance
* To comply with UL 985:Household Fire Warning System Units, the setting for Q46: Select Trouble Doesn’t Sound at Night must be set to (0)
Disabled.
** To comply with UL 1610: Central-Station Burglar-Alarm Units, Q96and Q97 must beset to (1) enabled. UL 1610 compliance also requires that
Q91: Select Radio Modem Supplier
be set to (1) Radio Modem Supplier 1.
Programming Question Table