background image

2

    Copyright © 2015 Nortek Security & Control LLC

Recessed Door Contact | Installation Instructions

Inserting and Replacing the Batteries

To

 

insert

 

or

 

replace

 

the

 

batteries:

1

Unwrap

 

the

 

door

 

contact.

2

Use

 

a

 

small

 

flat

head

 

screw

 

driver

 

to

 

push

 

the

 

clips

 

on

 

the

 

side

 

of

 

the

 

sensor

 

casing

 

in,

 

Then

 

remove

 

the

 

sensor

 

cap.

 

To

 

reach

 

the

 

battery,

 

you

 

must

 

remove

 

the

 

circuit

 

board

 

from

 

the

 

casing.

 

Before

 

removing

 

the

 

board,

 

it

 

is

 

important

 

to

 

observe

 

how

 

the

 

board

 

fits

 

into

 

the

 

grooved

 

channel

 

on

 

the

 

inside

 

of

 

the

 

sensor

 

cap.

 

When

 

replacing

 

the

 

board,

 

ensure

 

the

 

circuit

 

board

 

fits

 

back

 

into

 

the

 

channel

 

for

 

a

 

proper

 

fit.

 

Figure 3  

Battery Compartment and Polarity

3

Gently

 

remove

 

the

 

circuit

 

board

 

from

 

the

 

casing.

 

Notice

 

how

 

the

 

battery

 

compartment

 

is

 

built

 

into

 

the

 

end

 

of

 

the

 

circuit

 

board.

 

4

Remove

 

the

 

battery

 

from

 

the

 

compartment.

 

IMPORTANT: 

Always

 

dispose

 

and/or

 

recycle

 

used

 

batteries

 

in

 

accordance

 

with

 

the

 

hazardous

 

waste

 

recovery

 

and

 

recycling

 

regulations

 

for

 

your

 

location.

 

Your

 

city,

 

state,

 

or

 

country

 

may

 

also

 

require

 

you

 

to

 

comply

 

with

 

additional

 

handling,

 

recycling,

 

and

 

disposal

 

requirements.

 

5

Insert

 

the

 

new

 

or

 

replacement

 

battery

 

into

 

the

 

compartment.

 

Always

 

match

 

the

 

plus

 

(+)

 

sign

 

on

 

the

 

battery

 

with

 

the

 

flat

 

side

 

of

 

the

 

compartment

 

and

 

the

 

minus

 

(

)

 

sign

 

on

 

the

 

battery

 

with

 

the

 

spring

 

side.

6

Reinsert

 

the

 

circuit

 

board

 

to

 

fit

 

snugly

 

inside

 

casing

 

and

 

then

 

replace

 

the

 

sensor

 

cap,

 

taking

 

care

 

to

 

ensure

 

the

 

circuit

 

board

 

fits

 

properly

 

in

 

the

 

cap’s

 

grooved

 

channel.

 

WARNING: 

Failure

 

to

 

follow

 

these

 

warnings

 

and

 

instructions

 

can

 

lead

 

to

 

heat

 

generation,

 

rupture,

 

leakage,

 

explosion,

 

fire,

 

or

 

other

 

injury,

 

or

 

damage.

 

Do

 

not

 

insert

 

the

 

battery

 

into

 

the

 

compartment

 

in

 

the

 

wrong

 

direction.

 

Always

 

replace

 

the

 

battery

 

with

 

the

 

same

 

or

 

equivalent

 

type

 

(see

 

Specifications

).

 

Never

 

recharge

 

or

 

disassemble

 

the

 

battery.

 

Never

 

place

 

the

 

battery

 

in

 

fire

 

or

 

water.

 

Always

 

keep

 

batteries

 

away

 

from

 

small

 

children.

 

If

 

batteries

 

are

 

swallowed,

 

promptly

 

see

 

a

 

doctor.

 

SPECIFICATIONS

Wireless

 

Signal

 

Range

450

 

ft

 

(137.2

 

m),

 

open

 

air,

 

with

 

Wireless

 

Control

 

Panel

Code

 

Outputs

Alarm;

 

Alarm

 

Restore;

 

Supervisory;

 

Low

 

Battery

Transmitter

 

Frequency

345.00

 

MHz

 

(crystal

 

controlled)

Unique

 

ID

 

Codes

Over

 

one

 

(1)

 

million

 

different

 

code

 

combinations

Supervisory

 

Interval

70

 

minutes

Magnet

 

Dimensions

 

(HxD)

0.5

 

x

 

0.75

 

in

 

(1.27

 

x

 

1.9

 

cm)

 

typical

Magnet

 

Type

Rare

 

Earth

Sensor

 

Dimensions

 

(HxD)

2.57

 

x

 

0.75

 

in

 

(6.53

 

x

 

1.9

 

cm)

Weight

 

(including

 

battery

 

and

 

magnet)

1.25

 

oz

 

(35.4

 

g)

Housing

 

Material

ABS

 

Plastic

Color

White

 

or

 

Brown

Operating

 

Temperature

 

Limits

32°

 

to

 

120°

 

F

 

(0°

 

to

 

49°

 

C)

Relative

 

Humidity

5

95%

 

Non

Condensing

Battery

 

(installed

 

with

 

pull

 

tab)

One

 

(1)

 

3V

 

CR

2

 

or

 

equivalent

 

Lithium

 

battery

Certification

Anatel,

 

ETL,

 

FCC,

 

IC,

 

and

 

NOM

REGULATORY INFORMATION

FCC Notice

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC's

 

Rules.

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

1

This

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

2

This

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

This

 

equipment

 

generates,

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

receiver.

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

 

technician

 

for

 

help.

This

 

product

 

complies

 

with

 

FCC

 

radiation

 

exposure

 

limits

 

for

 

an

 

uncontrolled

 

environment.

 

Avoid

 

operating

 

this

 

product

 

at

 

a

 

distance

 

less

 

than

 

20

 

cm

 

from

 

the

 

user.

A

Battery

B

Door/Window

 

Contact

 

Housing

C

Battery

 

Case/PCB

D

Screw

 

Mount

 

Top

Отзывы: