If you detect abnormal combustion
or abnormal odors, or during an
earthquake, tornado or fire:
1. Turn off the hot water supply
2. Turn off the power to the water
heater
3. Turn off gas and water at the
main
4. Consult the nearest Noritz agent
This will prevent fire, electric shock or
damage to the unit.
Check the temperature of the
running hot water by hand before
taking a shower.
Also check the temperature by
hand before stepping into the bath
tub.
Do not turn off the water heater or
change the water temperature while
someone is bathing.
This can result in scalding or temperature
shock.
Leave the proper clearance between
the water heater and nearby objects
(trees, timber, boxes with flammable
materials etc.).
Do not place or use a spray can
near the heater or the exhaust vent
terminal.
This may result in an explosion or fire.
*
Indicates suggested clearances for
maintenance.
Left side:
Min. 2"
Right side:
Min. 2"
Min. 3" from
exhaust pipe
Front:
Min. 24"
*
Do not place combustibles such as
laundry, newspapers, oils etc. near
the heater or the exhaust vent
terminal.
These may cause a fire.
Do not use combustible chemicals
such as oil, gasoline, benzene etc.
in the vicinity of the heater or the
exhaust vent terminal.
These may cause a fire.
Check the air supply vent for dust
or obstructions.
Exhaust vent
terminal
Be sure the gas supplied matches
the gas on the rating plate.
Using an improper gas or electric supply
may cause improper operation, fire or
electric shock.
Do not allow small children to play
unsupervised in the bathroom.
Do not allow small children to
bathe unsupervised.
Accidents may occur.
Consult the nearest Noritz agent if
the water heater location needs to
be changed.
Contact a qualified service
technician for any necessary
repairs, service or maintenance.
Warning
Warning
IMPORTANT SAFETY INFORMATION
-2
Manufacturing year and month
X X X X . X X - X X X X X X
Top of heater
S E R I A L N U M B E R
Back of heater
Front of heater
Side of heater
Minimum Clearances from Combustible of Non-combustible Construction
Clearance
M a d e i n J A P A N
X X X X X X X X X X
Type of Gas : Natural Gas
Max. Water Pressure : Min. 15psi ~ Max. 150 psi
Electrical Rating : AC 120 Volts 60 Hz
Manifold Gas Pressure : Min. 0.63 ~ Max. 2.3 inches
Inlet Gas Pressure : Min. 3.5 ~ Max. 10.5 inches
Recovery Rate : 241 Gallons/Hour
BTU Input : Max. 179,000 ~ Min. 22,000
Model : N-063
Tel : (949)420-0409
20492 Crescent Bay Dr.Ste.104.Lake Forest CA 92630
NORITZ AMERICA CORPORATION
Automatic Instantaneous Water Heater
REQUIRED CLEARANCES TO COMBUSTIBLES
ANSI Z21.10.3 2000
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliances
Outdoor Install
Indoor Install
36 inches
1 inch
24 inches
6 inches
2 inches
4 inches
1 inch
12 inches