26
27
Specifications
Specifications
•
Specifications may be changed without prior notice.
•
The capacity may differ slightly, depending on the water pressure,
water supply, piping conditions, and water temperature.
Performance table
External outfitting
Item
Gas
Consumption
Hot Water
Capacity
Capacity Range
Temperature Settings
Default Temperature Options
NG
LP
45
°
F Rise
72
°
F Rise
6.3 Gal./min.
4.0 Gal./min.
0.75-6.3 Gal./min.
99-118,140,167
°
F(14 Options)
108,113,140,167
°
F(Original is 108
°
F)
Maximum Performance
179,000 btuh
179,000 btuh
Minimum Performance
22,000 btuh
22,000 btuh
Specification
N-063
Indoor or Outdoor, Wall Hanging
Power Vented
Direct Ignition
15-150 PSI
0.75 GPM
20.5"(Height) x 13.8"(Width) x 6.7"(Depth)
38 lbs.
0.2 Gallon
3/4"
3/4"
1/2"
120 VAC (60Hz)
NG: XXXW, LP: XXXW, Freeze Prevention 125W
Zincified Steel Plate/Acryl Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR), Electric Leakage
Prevention Device, Overheat Prevention Device,
Freezing Prevention Device, Fan Rotation Detector
Temperature Control Panel, Anchoring Screws
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Safety Devices
011
032
032
031
002
009
010
007
005
004
006
003
001
014
012
013
Содержание N-063