31
4-8.
Setting the Control Panel. (Recirculation mode)
Setting the Control Panel
Chapter 4. – Installation
►To use the ‘
Recirculation Timer Mode
’, the device’s internal clock should be adjusted to the current time.
Clock settings can be set in the ‘User mode’.
Clock Adjustment
· Set in ‘[L:TA] mode’ after turning the ‘Dial Button’ in ‘User Mode’.
· Set the YEAR - MONTH - DAY - DAY OF THE WEEK - HOUR - MINUTE in regular sequence..
Press the dial
button to store
the setting.
Press the dial
button to store
the setting.
1. Setting year : 2014
Set the ‘Year’ by turning the dial button.
(Only the flashing number can be changed.)
Set the ‘month’ by turning the dial button.
(Only the flashing number can be changed..)
Press and hold ‘Function Button’ for
approximately 5 Seconds to enter ‘User
mode’.
Power on the control panel must be on.
‘[A:GA]’ is displayed on the display screen.
From here, turn the ‘Dial Button’ to start the
setting.
Turn the dial button clockwise until
‘[L:TA]’ is displayed.
2. Setting month : 7
[ To enter ‘
User Mode
’ ]
Enter the clock ‘Setting mode’ by pressing dial
button when flashing the [L:TA] character.
Customer can set the
current date, time and
day in ‘[L:TA] mode’.
Содержание Eco TOUGH NRCP111-DV-LP