36
Quick Connect
Chapter 4. – Installation
Connecting the Quick Connect Cable to the two units.
1. Turn off the power.
2. Remove the front covers for both of the heaters (4 screws each)
3. Pass the Quick Connect Cord through the wiring throughway at the bottom of the units.
4. Plug the wire connector into the ‘Main PCB’ connector inside both units.
5. Replace the front covers.
6. Turn on the power.
※
All units must be set to the same settings listed below before using in the Quick Connect Multi System.
1. Set “on” at [6:QC] in installer mode (Refer to below)
2. Current Clock Setting. (Refer to page 31 in the Installation Manual)
3. Recirculation Timer Setting, if recirculation is used. (Please refer to pages 22-27 in the Owner’s Guide)
<Note>
CA:01(Master) unit will be able to set as first setting “on” at [6:QC] in installer mode.
Other unit will be automatically set CA:02(Slave) as second setting “on” at [6:QC] in installer mode.
1. Turn off the power to the control panel. Press and hold the
‘Function Button’ for 5 seconds to get into the ‘Installer mode’.
2. Turn the dial button to ‘[6:QC]’
3. Press the dial button, the “oFF” character will now be
flashing.
4. Turn the dial button clockwise to select ‘on’ in order to
activate Quick Connect Multi System function.
5. Press the dial button to store the current setting and
return back to ‘Installer mode’.
Index
Parameter
Description
Quick connect mode : Master water heater
If ‘Quick connect mode’ is activated, [CA01]/[CA02]
character appears on the display screen..
Quick connect mode : Slave water heater
<Note>
Auto (Self Learning Mode) Recirculation function is not available with the Quick Connect Systems.