![NORIS FA13 Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/noris/fa13-series/fa13-series_instruction-manual_1705042015.webp)
NORIS Automation GmbH
General technical data | 3
Instruction manual FA13
15 / 44
General technical data
Electrical connection
Supply voltage
See specific technical data
Nominal voltage
See specific technical data
Current consump-
tion
See specific technical data
Reverse voltage
protection
Yes
Over voltage pro-
tection
Yes
Connection
See specific technical data
Recommended
cable length
< 100 m
Used cable cross
section
0.33 mm², shielded
Electrical output
Measuring chan-
nels
See specific technical data
Output signal and
signal type
See specific technical data
Output stage
Push-pull amplifier
Continuous short
circuit protection
Yes
Galvanic isolation
See specific technical data
Output level Low
See specific technical data
Output level High
See specific technical data
Output current
NPN (Sink)
See specific technical data
Output current
PNP (Load)
See specific technical data
Internal resist-
ance Ri
See specific technical data
Rise time
≥ 10 V/µs
Signal acquisition
Measuring princi-
ple
FA
H
[..] series: Difference-Hall
FA
J
[..] series: Inductive-magnetic
Frequency range
See specific technical data
Scanning type
Non-contacting
Scanning object -
distance
0.2 ... 3 mm; recommended: 1.0 ± 0.5 mm
Scanning object
See specific technical data
Duty cycle
50% ± 10%
Phase shift
See specific technical data