AIRFLOW DATA

*SA - UPFLOW / HORIZONTAL FURNACES - 80+ AFUE

Model Number

&

Heating Input

(Btuh)

Motor

Speed

External Static Pressure (Inches Water Column)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

CFM

Rise

SA045C-23A

Bottom Return

(45,000)

High*

1,260

26

1,205

28

1,145

29

1,080

31

1,025

33

960

35

890

37

825

40

Med-High

955

35

950

35

940

35

935

36

925

36

860

39

800

42

725

46

Med-Low**

825

40

800

42

760

44

730

46

690

48

650

51

600

56

530

63

Low

655

51

630

53

610

55

580

57

550

61

520

64

480

69

435

77

SA045C-23A

Side Return

(45,000)

High*

1,350

25

1,290

26

1,225

27

1,155

29

1,100

30

1,025

33

950

35

885

38

Med-High

1,025

33

1,015

33

1,005

33

1,000

33

990

34

920

36

855

39

775

43

Med-Low**

885

38

855

39

815

41

780

43

740

45

695

48

640

52

565

59

Low

700

48

675

49

655

51

620

54

590

56

555

60

515

65

465

72

SA054C-23A

Bottom Return

(54,000)

High*

1,260

32

1,205

33

1,145

35

1,080

37

1,025

39

960

42

890

45

825

48

Med-High**

955

42

950

42

940

43

935

43

925

43

860

47

800

50

725

55

Med-Low

825

48

800

50

760

53

730

55

690

58

650

62

600

67

530

75

Low

655

61

630

63

610

66

580

69

550

73

520

77

480

83

435

92

SA054C-23A

Side Return

(54,000)

High*

1,350

30

1,290

31

1,225

33

1,155

35

1,100

36

1,025

39

950

42

885

45

Med-High**

1,025

39

1,015

39

1,005

40

1,000

40

990

40

920

43

855

47

775

52

Med-Low

885

45

855

47

815

49

780

51

740

54

695

58

640

63

565

71

Low

700

57

675

59

655

61

620

65

590

68

555

72

515

78

465

86

SA072C)-24B

Bottom Return

(72,000)

High*

1,685

32

1,640

33

1,605

33

1,565

34

1,515

35

1,475

36

1,415

38

1,345

40

Med-High

1,330

40

1,295

41

1,275

42

1,245

43

1,215

44

1,185

45

1,135

47

1,070

50

Med-Low**

1,175

45

1,155

46

1,125

47

1,100

48

1,075

50

1,045

51

1,010

53

955

56

Low

930

57

895

60

885

60

850

63

825

65

800

67

770

69

740

72

SA072C-24B

Side Return

(72,000)

High*

1,770

30

1,720

31

1,685

32

1,645

32

1,590

34

1,550

34

1,485

36

1,415

38

Med-High

1,400

38

1,360

39

1,340

40

1,310

41

1,275

42

1,245

43

1,190

45

1,125

47

Med-Low**

1,235

43

1,215

44

1,180

45

1,155

46

1,130

47

1,100

48

1,060

50

1,005

53

Low

975

55

940

57

930

57

890

60

865

62

840

63

810

66

775

69

SA090C-24B

Bottom Return

(90,000)

High*

1,610

41

1,575

42

1,530

44

1,485

45

1,440

46

1,385

48

1,340

50

1,275

52

Med-High**

1,295

51

1,260

53

1,235

54

1,220

55

1,175

57

1,135

59

1,095

61

1,015

66

Med-Low

1,155

58

1,130

59

1,100

61

1,070

62

1,035

64

1,015

66

965

69

920

72

Low

880

76

860

78

830

80

800

83

765

87

740

90

675

99

660

101

SA090C-24B

Side Return

(90,000)

High*

1,690

39

1,655

40

1,610

41

1,560

43

1,510

44

1,455

46

1,405

47

1,340

50

Med-High**

1,360

49

1,325

50

1,300

51

1,280

52

1,235

54

1,190

56

1,150

58

1,065

63

Med-Low

1,215

55

1,190

56

1,155

58

1,125

59

1,090

61

1,065

63

1,015

66

965

69

Low

925

72

900

74

870

77

840

79

800

83

775

86

710

94

695

96

SA072C-35C

Bottom Return

(72,000)

High*

1,950

27

1,865

29

1,790

30

1,715

31

1,630

33

1,550

34

1,475

36

1,390

38

Med-High

1,860

29

1,780

30

1,710

31

1,635

33

1,575

34

1,500

36

1,415

38

1,325

40

Med-Low**

1,300

41

1,240

43

1,200

44

1,160

46

1,120

48

1,065

50

995

54

910

59

Low

1,165

46

1,115

48

1,060

50

1,025

52

985

54

940

57

890

60

825

65

SA072C-35C

Side Return

(72,000)

High*

2,030

26

1,940

27

1,860

29

1,785

30

1,695

31

1,615

33

1,535

35

1,445

37

Med-High

1,935

28

1,850

29

1,780

30

1,700

31

1,340

40

1,560

34

1,470

36

1,380

39

Med-Low**

1,350

40

1,290

41

1,250

43

1,205

44

1,165

46

1,110

48

1,035

52

945

56

Low

1,215

44

1,160

46

1,105

48

1,065

50

1,025

52

980

54

925

58

860

62

SA072C-35C

Side + Bottom

or 2 Sides

(72,000)

High*

2,050

26

1,960

27

1,880

28

1,800

30

1,710

31

1,630

33

1,550

34

1,460

37

Med-High

1,955

27

1,870

29

1,800

30

1,715

31

1,655

32

1,575

34

1,485

36

1,390

38

Med-Low**

1,365

39

1,300

41

1,260

42

1,220

44

1,175

45

1,120

48

1,045

51

955

56

Low

1,225

44

1,170

46

1,115

48

1,075

50

1,035

52

985

54

935

57

865

62

Table 4. Maximum Airfl ow & Temperature Rises (° F) - Upfl ow / Horizontal Furnaces

Содержание *SA Upfl ow / Horizontal

Страница 1: ...upplier s instructions If you cannot reach your gas supplier call the fire department WARNING RISQUE D INCENDIE OU D EXPLOSION Le non respect des avertissements de s curit pourrait entra ner des bless...

Страница 2: ...r Connections 11 Upflow Horizontal Furnaces 11 Side Return Installations 11 Bottom Return Installations 12 Downflow Furnaces 12 Acoustical Treatments 12 FURNACE INSTALLATION 12 General Requirements 12...

Страница 3: ...ry or death This furnace must be installed in accordance with these instructions all applicable local building codes and the current revision of the National Fuel Gas Code NFPA54 ANSI Z223 1 or the Na...

Страница 4: ...ermostat The installation must include a properly installed filter in the return air system with no by pass air The filter must be inspected frequently and replaced when necessary Combustion air must...

Страница 5: ...opane Installation Codes NSCNGPIC Venting Systems and Air Supply for Appliances Duct Systems US and CANADA Air Conditioning Contractors Association ACCA Manual D Sheet Metal and Air Conditioning Contr...

Страница 6: ...n vacuent correctement tel que prescrit ci dessus rouvrir les portes et les fen tres et remettre les ventilateurs d vacuation les registres de foyers et tout autre appareil fonctionnant au gaz leur ta...

Страница 7: ...air from that space Furnaceclosets smallequipmentroomsandgaragesare confined spaces Furnaces installed in a confined space which supply heated air to areas outside the space must draw return air from...

Страница 8: ...or Wall 12 Max 12 Max Furnace NOTE Each opening to outside must be at least 1 sq in per 4 000 Btuh of total input rating Vent or Chimney Water Heater See Note Total Input Rating Btuh Minimum Free Area...

Страница 9: ...ve pressure draft and must be vented vertically or near vertical Additionally it is important to guard against excessive condensation WARNING Upon completion of the furnace installation carefully insp...

Страница 10: ...xisting vent system should also be checked to make sure it remains in compliance with NFGC If it isn t the vent system must be brought into compliance before installing the furnace Horizontal Venting...

Страница 11: ...e furnace is equal to the return air supply under normal indoor return air applications When a cooling system is installed which uses the furnace blower to provide airflow over the indoor coil the coi...

Страница 12: ...ur knockouts to expose the blower assembly Position the return air duct over the opening in the side and secure together with sheet metal screws The screws must penetrate the duct and furnace casing W...

Страница 13: ...hers Securethesupportframetothe rafters with lag bolts The furnace can also be suspended using steel straps around each end of the furnace The straps should be attached to the furnace with sheet metal...

Страница 14: ...e the furnace in reverse order Bottom Panel Removal The steps listed below describe how to remove the bottom panel from the furnace See Figure 11 1 Remove the door 1 from the blower compartment 2 Disc...

Страница 15: ...IPING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage Installation and service must be performed by a qualified installer service a...

Страница 16: ...2 000 feet the input needs to be reduced 8 at 3 000 feet 12 etc This deration is in reference to the input rate and gas heating value at sea level Toderatethefurnacerequiresknowingtheheatingvalueof t...

Страница 17: ...TATUS FLAME 180 COOL HEAT 120 90 60 BLOWER OFF DELAY LOW ML MH HIGH EAC L1 XFMR HUM 24V L1A 5 NEUTRALS 2 6 3 4 1 7 8 9 5 2 6 3 4 1 FAN 8 3 5 See Note R C Y G W STATUS FLAME 180 COOL HEAT 120 90 60 BLO...

Страница 18: ...erty damage Before servicing disconnect all electrical power to furnace When servicing controls label all wires prior to disconnecting Reconnect wires correctly Verify proper operation after servicing...

Страница 19: ...is connected Furnace Model SA SK Furnace Input Btuh Cabinet Width in Nominal Electrical Supply Maximum Operating Voltage Minimum Operating Voltage Maximum Furnace Amperes Minimum Wire Gauge Maximum F...

Страница 20: ...municate to a fixed speed or variable speed high efficiency motor that may be optionally installed Please contact your distributor for the proper upgrade motor kit Heat Anticipator Set the heat antici...

Страница 21: ...cal power to the furnace 3 FollowtheOperatingInstructionsonthelabelattached to the furnace 4 Setthethermostataboveroomtemperatureandverify the Operating Sequence Page 22 5 After 5 minutes of operation...

Страница 22: ...t switch should turn off the gas valve when the return is blocked time depends on how well the return air is blocked The circulating air and combustion blowers should continue to run when the limit sw...

Страница 23: ...will close the gas valve and initiate the shutdown cycle GasValve Controls the flow of gas to the burners When the gas valve is energized it automatically opens and regulates the gas pressure in the...

Страница 24: ...urnace 4 Turn the gas control switch to the OFF position 5 Disconnect the wires from the gas valve igniter flame sensor and flame rollout switch CAUTION To prevent damage to the unit or internal compo...

Страница 25: ...ays however the flue vent system and burners should be inspected and cleaned if required by a qualified service technician annually to ensure continued safe operation Pay attention to any deterioratio...

Страница 26: ...23A 072C 24B 17 1 2 11 3 4 15 7 8 16 1 8 090C 24B 072C 35C 21 14 19 3 8 19 7 8 090C 35C 108C 35C 126C 45D 24 1 2 15 1 4 22 7 8 23 1 8 NOTE Dimensions shown in Inches 18 5 8 C 7 34 1 2 22 1 2 28 25 3 8...

Страница 27: ...685 32 1 645 32 1 590 34 1 550 34 1 485 36 1 415 38 Med High 1 400 38 1 360 39 1 340 40 1 310 41 1 275 42 1 245 43 1 190 45 1 125 47 Med Low 1 235 43 1 215 44 1 180 45 1 155 46 1 130 47 1 100 48 1 060...

Страница 28: ...63 1 225 65 1 175 68 SA108C 35C Side Return 108 000 High 2 295 35 2 235 36 2 180 37 2 110 38 2 050 39 1 975 41 1 900 42 1 810 44 Med High 2 130 38 2 075 39 2 035 39 1 970 41 1 915 42 1 845 43 1 765 4...

Страница 29: ...51 1 300 51 1 280 52 1 255 53 1 230 54 1 200 56 1 150 58 Med Low 1 180 56 1 165 57 1 150 58 1 135 59 1 115 60 1 090 61 1 060 63 1 010 66 Low 940 71 925 72 900 74 880 76 850 78 825 81 795 84 760 88 SK...

Страница 30: ...n Yellow LED Continuous Flash On Alternating Flash IGNITOR INDUCER FLAME SENSOR C BLOWER LIMIT SWITCH DOOR SWITCH R 4 SPEED MOTOR WHITE RED BLUE ORANGE BLACK BLOWER LIMIT SWITCH GAS VALVE H MH ML L C...

Страница 31: ...ER REVOLUTION OF GAS METER 1 5 10 10 360 1 800 3 600 12 300 1 500 3 000 14 257 1 286 2 571 16 225 1 125 2 250 18 200 1 000 2 000 20 180 900 1 800 22 164 818 1 636 24 150 750 1 500 26 138 692 1 385 28...

Страница 32: ...57 57 ORIFICE SIZE 9 0 9 0 9 0 9 0 9 0 9 0 MANIFOLD PRESSURE 8 000 to 10 000 FT 59 57 57 57 57 57 ORIFICE SIZE 8 5 8 5 8 5 8 5 8 5 8 5 MANIFOLD PRESSURE LOCAL HEATING VALUES FOR NATURAL GAS ALTITUDE...

Страница 33: ...LD PRESSURE 9 000 to 9 999 FT 51 49 49 49 49 49 ORIFICE SIZE 2 6 2 8 2 8 2 8 2 8 2 8 MANIFOLD PRESSURE Table 11 High Altitude Deration Chart for Natural Gas Low Heating Value NATURAL GAS with LOW HEAT...

Страница 34: ...oll Out Switch Transformer Blower Assembly Control Board Main Air Limit Switch Figure 20 Furnace Components Combustion Tube Gas Manifold Gas Valve Inducer Assembly Control Board Pressure Switch Transf...

Страница 35: ...35...

Страница 36: ...tion of this appliance Some local codes require licensed installation service personnel for this type of equipment Please read all instructions carefully before starting the installation Return these...

Отзывы: