background image

Trilogy

r

 Air Spray/LVLP Automatic Spray Guns

3

Part 1601058

03

E

 2014 Nordson Corporation

WARNING:

 

 

Any injury caused by high pressure liquid can be serious.  If

you are injured or even suspect an injury:

S

Go to an emergency room immediately.

S

Tell the doctor that you suspect an injection injury.

S

Show him this card

S

Tell him what kind of material you were spraying

MEDICAL ALERT—AIRLESS SPRAY WOUNDS:  NOTE TO PHYSICIAN

Injection in the skin is a serious traumatic injury.  It is important to treat the

injury surgically as soon as possible.  Do not delay treatment to research

toxicity.  Toxicity is a concern with some exotic coatings injected directly into

the bloodstream.

Consultation with a plastic surgeon or a reconstructive hand surgeon may

be advisable.

The seriousness of the wound depends on where the injury is on the body,

whether the substance hit something on its way in and deflected causing

more damage, and many other variables including skin microflora residing in

the paint or gun which are blasted into the wound.  If the injected paint

contains acrylic latex and titanium dioxide that damage the tissue’s

resistance to infection, bacterial growth will flourish.  The treatment that

doctors recommend for an injection injury to the hand includes immediate

decompression of the closed vascular compartments of the hand to release

the underlying tissue distended by the injected paint, judicious wound

debridement, and immediate antibiotic treatment.

Fire Safety 

To avoid a fire or explosion, follow these instructions.

S

Ground all conductive equipment.  Use only grounded air and fluid
hoses.  Check equipment and workpiece grounding devices regularly.

Resistance to ground must not exceed one megohm.

S

Shut down all equipment immediately if you notice static sparking or
arcing.  Do not restart the equipment until the cause has been identified

and corrected.

S

Do not smoke, weld, grind, or use open flames where flammable
materials are being used or stored.

S

Do not heat materials to temperatures above those recommended by
the manufacturer.  Make sure heat monitoring and limiting devices are

working properly.

Содержание Trilogy AS

Страница 1: ...14 NORDSON CORPORATION AMHERST OHIO USA For parts and technical support call the Industrial Coating Systems Customer Support Center at 800 433 9319 or contact your local Nordson representative This do...

Страница 2: ...acement 13 Parts 13 Options 15 Contact Us Nordson Corporation welcomes requests for information comments and inquiries about its products General information about Nordson can be found on the Internet...

Страница 3: ...t 1601058 03 E 2014 Nordson Corporation Change Record Revision Date Change 02 7 13 Added compliance kits and air caps and instructions 03 3 14 Added Parts information for the Trilogy AS Automatic gun...

Страница 4: ...Change Record ii Part 1601058 03 E 2014 Nordson Corporation...

Страница 5: ...their assigned tasks They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks Intended Use Use of Nordson equipment in ways other...

Страница 6: ...diately Do not restart the equipment until the problem has been identified and corrected S Obtain and read Material Safety Data Sheets MSDS for all materials used Follow the manufacturer s instruction...

Страница 7: ...microflora residing in the paint or gun which are blasted into the wound If the injected paint contains acrylic latex and titanium dioxide that damage the tissue s resistance to infection bacterial gr...

Страница 8: ...e for parts information and advice Halogenated Hydrocarbon Solvent Hazards Do not use halogenated hydrocarbon solvents in a pressurized system that contains aluminum components Under pressure these so...

Страница 9: ...compliance caps and gauge kits to test air flow and ensure compliance with regulations Refer to Compliance Kit Installation and Use for instructions Specifications Item Specification Weight 850 grams...

Страница 10: ...ed environments Use in zone 1 equipment of category 2 S The following harmonized standards or parts from this were used S DIN EN ISO 12100 2011 Safety of machines S EN 349 Minimum distances to avoid s...

Страница 11: ...control of coating atomization and fan pattern shape 4 Connect the fluid delivery and return hoses to the 3 8 NPSM US or 1 4 G metric fittings 2 NOTE Before using your spray gun for production flush...

Страница 12: ...ng are the adjustments that can be made to the spray pattern Item Description Adjustment Port R Atomizing air Increase for finer spray decrease for coarser spray Manual control Turn regulator clockwis...

Страница 13: ...ired but it will prevent fluid from spraying while performing the compliance test 2 Remove the retainer and production air cap from the gun Install the compliance air cap on the gun and tighten the re...

Страница 14: ...e WARNING Allow only qualified personnel to perform the following tasks Follow the safety instructions in this document and all other related documentation Cleaning 1 Flush the gun with solvent or wat...

Страница 15: ...e too big or worn out Replace the nozzle Viscosity too high Lower the material viscosity Either not enough or no atomizing air Adjust atomizing air flow regulator R Air cap orifices clogged Use a soft...

Страница 16: ...seal 3 and replace it if damaged 3 Install a new nozzle in the gun 4 Install the seal on the nozzle 5 Install the air cap in the retainer and install them on the gun Orient the air cap as desired then...

Страница 17: ...7 Install the chamber nut over the packing gland and tighten it securely 8 Install the needle as described in Needle Replacement Piston Replacement 1 See Figure 5 Remove the needle as described in Nee...

Страница 18: ...1 1 1601045 S Retainer air cap LP Trilogy NES 1 2 1600932 S Air cap 0 5 1 2 mm LP Trilogy NES 1 2 1600935 S Air cap 0 5 1 2 mm AS auto Trilogy NES 1 A D 2 1600936 S Air cap 1 3 1 6 mm AS auto Trilogy...

Страница 19: ...plete LP Trilogy NES 1 21a S S Ring seal 1 B C 21b S S Gasket piston 1 B C 21c S S O ring 16 x 2 0 2 B C 21d S S Ring square 2 B C 21e S S Seal take up complete 1 B C 211f S S Nut jam 1 B C 22 1601824...

Страница 20: ...1601856 Kit nozzle 0 8 mm LP Trilogy NES 1600976 Kit nozzle 1 0 mm LP Trilogy NES 1601857 Kit nozzle 1 2 mm LP Trilogy NES 1601858 Kit nozzle 1 3 mm LP Trilogy NES 1601859 Kit nozzle 1 4 mm LP Trilog...

Страница 21: ...s and Gauge Kit 1603866 Cap air test Trilogy LVLP size A 0 5 1 2 mm A 1603867 Cap air test Trilogy LVLP size B 1 3 1 6 mm A 1603868 Cap air test Trilogy LVLP size C 1 8 2 5 mm A 1603869 Cap air test T...

Страница 22: ...Trilogyr Air Spray LVLP Automatic Spray Guns 18 Part 1601058 03 E 2014 Nordson Corporation NOTES...

Отзывы: