Troubleshooting
6-7
Part
E
2012 Nordson Corporation
Corrective Action
Possible Cause
Problem
Color change does
not start
E-Stop button pressed
Reset E-Stop button.
Afterfilter exhaust fan not running,
or fan interlock circuit defective
Turn on exhaust fan. Check fan
interlock wiring between feed center
panel and main system panel.
PLC not initiating color change
sequence.
Check PLC operation. Contact your
Nordson representative or technical
support center for help.
Parts still in booth
iControl system tracks parts through
booth and will delay color change
start until parts clear booth. Booth
length is configurable through
iControl Configuration. Refer to
iControl Operator Interface manual
for more information.
iControl gun positioners not in
manual or auto mode
Set the gun positioners to either
manual or auto mode.
iControl gun positioner #1
controller did not receive Color
Change start signal from feed
center
The feed center passes signals for
color change to the gun positioner #1
electrical panel which then
communicates with the iControl
system.
Check the wiring and connections
between the feed center control
panel and the gun positioner #1
panel.
Reciprocator not in auto mode
Reciprocator must be in auto mode
for color change cycle to start.
Set the reciprocator to auto mode.