HDLV Transfer Pump Maintenance
For more detailed maintenance and repair information, refer to the Prodigy
HDLV High-Capacity Pump manual.
Component
Maintenance Procedure
HDLV Reclaim and
Virgin Transfer Pumps
Daily
Inspect the pinch valve body for signs
of powder leakage. If you see powder
in the pinch valve body or stress
cracks in the pinch valves, replace
the pinch valves.
Pinch Valves
Kit 1057265
Every Six Months or
Each Time You Disassemble the
Pump
Disassemble the pump assembly and
inspect the lower Y body and upper
Y-manifold for signs of wear or impact
fusion. Clean these parts in an
ultrasonic cleaner if necessary.
NOTE:
To reduce downtime, keep a
spare upper Y-manifold and lower Y
body in stock to install while you are
cleaning the other set.
Upper Y-Manifold
Kit 1057269
Lower Y Body
Part 1053976
Cleaning
CAUTION:
Clean any impacted powder with clean cloths being careful not
to make contact with any plastics or painted surfaces.