Rhino VE/CE Pneumatic Level Detect Modules
2
Part 1603025--01
E
2012 Nordson Corporation
Repair
Repairs consist of replacing the actuating rod wiper seal
along with replacing and adjusting the roller plunger
limit switches.
WARNING
S
Allow only qualified personnel to perform the
following tasks. Follow the safety
instructions in this document and all other
related documentation.
S
Disconnect and lock out power to the system
before performing repairs.
Wiper Seal
1. See Figure 2. Remove the screws (6) and
washers (5) securing the cover (4) to the base
plate (9).
2.
Large Frame:
Remove the screws (1) and
washers (2) securing the bracket (7) to the crossover
bar (3).
Small Frame:
Remove the screws (16) and
washers (17) securing the bracket (18) to the base
plate (19).
3. Remove the actuating rod assembly (8) from the
guide tube (11).
4. Loosen the screw (15) on the split collar (14). Push
the guide tube (13) downward to access the wiper
seal (10). Remove the wiper seal from the base
plate (9) and discard.
5. Assembly is the reverse order of disassembly. Verify
the settings of the limit switches (12) before installing
the cover (4).
WIPER ORIENTATION
13
15
14
12
2
1
7
3
5
6
4
18
19
SMALL FRAME
11
9
10
8
16
17
Figure 2
Typical Wiper Seal Replacement
(Large Frame Shown)