Rhino VE/CE Pneumatic Level Detect Modules
3
Part 1603025--01
E
2012 Nordson Corporation
Limit Switch
1. See Figure 2. Remove the screws (6) and
washers (5) securing the cover (4) to the base
plate (9).
2. See Figure 3. Disconnect the tubing (4) from the
fittings (3).
3. Remove the lock nut (6), washer (5), and screws (1)
securing the limit switch (2) to the bracket (7).
4. Remove the fittings (3) and install them onto the new
limit switch (2).
5. Install the new limit switch (2) to the bracket (7) using
the screws (1), washers (5), and lock nuts (6). Do
not tighten the screws at this time.
6. Connect the tubing (4) to the fittings (3).
7. Slide the limit switch (2) toward the actuating rod (8)
until the limit switch roller plunger is compressed
0.060--0.090 in. (1.54--2.28 mm). Tighten the
screws (1) securely.
8. Verify the settings of the limit switch (2).
9. See Figure 2. Install the cover (4) to the base
plate (9) using the screws (6) and washers (5).
Tighten the screws securely.
0.060--0.090 IN. (1.54--2.28 MM) BEFORE
ROLLER PLUNGER MUST BE COMPRESSED
TIGHTENING THE SCREWS.
SLIDE LIMIT SWITCH TOWARD ACTUATING ROD.
8
2
5
3
4
6
1
4
3
7
Figure 3
Typical Limit Switch Replacement