background image

NPE-LF10 and NPE-HF10 Powder Spray Guns

4

Part 108191C

E

 2003 Nordson Corporation

Safety Label 

Table 1 contains the text of the safety label on this equipment.  The safety

label is provided to help you operate and maintain your equipment safely.

Table 1  Safety Label 

 

Part

Description

244644

WARNING:

  The following procedures MUST be followed when working with

this electrostatic spray equipment.  Failure to follow these instructions may

result in a fire and/or serious personal injury.  Display this warning on the spray

booth.

1. NO SMOKING.  Keep open flames, hot surfaces, and sparks from torches or

grinding away from booth.

2. Turn the electrostatic power unit off when the spray gun is not in use.

3. Shut down immediately in event of fire.

4. Maintain ground circuit on all conductive objects below 1 megohm to prevent

sparking.  (ANSI/NFPA 33, Chapter 9, or local codes).

5. Shut down operation and correct grounds if sparking occurs.

6. Install fixed fire suppression system in accordance with ANSI/NFPA 33,

Chapter 7 (or local codes), before operating with combustible powder.

7. Install automatic flame detectors in accordance with ANSI/NFPA 33,

Chapter 7 (or local codes), before operating automatic guns

8. Examine all equipment at the beginning of each work period and repair or

replace any damaged, loose, or missing parts.

9. Before cleaning or performing any maintenance on the electrostatic spray

gun, turn off the power unit and ground the nozzle.  Maintain electrostatic

spray equipment in accordance with instruction manual.  Do not deviate.  Do

not substitute parts from other manufacturers.

10. Operator must be grounded to prevent shocks from static electricity.  Floor

surface must be conductive.  Footwear and gloves must be static dissipative

in accordance with ANSI Z41-1991 (or local codes).

11. Air velocity through all booth openings must meet local requirements and

contain powder within the booth.  If powder escapes from the booth, shut

down operation and correct the malfunction.

12. Powder may be toxic or be a nuisance dust hazard.  Refer to supplier’s

MSDS.  If exposed to dust during operation, maintenance, or clean up,

operators must use appropriate personal protective equipment.

13. Do not use compressed air or organic solvents for removal of powder from

skin or clothing.  Do use soap and water.  Wash hands before eating or

smoking.

14. Guns, feeders, booths, etc., may be cleaned with clean dry air at 1.7 bar

(25 psig).

If you have any questions concerning this electrostatic spray equipment, call

(440) 988-9411, and ask to speak with the Powder Systems Group Technical 

Service Department.

Содержание NPE-HF10

Страница 1: ...DSON CORPORATION AMHERST OHIO USA For parts and technical support call the Industrial Coating Systems Customer Support Center at 800 433 9319 or contact your local Nordson representative This document...

Страница 2: ...16 Options 18 Conversion Kits 18 Contact Us Nordson Corporation welcomes requests for information comments and inquiries about its products General information about Nordson can be found on the Inter...

Страница 3: ...relevant safety rules and regulations and are physically capable of performing their assigned tasks Intended Use Use of Nordson equipment in ways other than those described in the documentation suppli...

Страница 4: ...al protection devices S To prevent injury be aware of less obvious dangers in the workplace that often cannot be completely eliminated such as hot surfaces sharp edges energized electrical circuits an...

Страница 5: ...e spray area must be grounded S There is a possible ignition potential from the charged human body Personnel standing on a painted surface such as an operator platform or wearing non conductive shoes...

Страница 6: ...guns 8 Examine all equipment at the beginning of each work period and repair or replace any damaged loose or missing parts 9 Before cleaning or performing any maintenance on the electrostatic spray g...

Страница 7: ...which are interchangeable Conversion kits are available one to convert a LF10 to a HF10 and one to convert a HF10 to a LF10 Different pumps and hoses are used with each version and must be ordered se...

Страница 8: ..._F or lower dewpoint at 6 89 bar 100 psi Installation WARNING Allow only qualified personnel to perform the following tasks Follow the safety instructions in this document and all other related docume...

Страница 9: ...the spray gun on a reciprocator secure the cable so it will not be damaged by repeated rubbing against nearby equipment or the floor Allow enough slack to prevent any strain on the cable CAUTION Clea...

Страница 10: ...prevent it from kinking where it connects to the powder tube NOTE If possible the powder feed hose should be no longer than 8 m 25 ft Longer lengths will decrease the flow of powder and may cause unev...

Страница 11: ...supply manual typical pressure is 0 7 1 03 bar 10 15 psi Allow time for the powder to become completely fluidized before spraying 4 Turn on the power unit Adjust the air pressures as follows Air Setti...

Страница 12: ...both 8 and 16 m cables guns without tip resistor NOTE The tip resistor electrode assembly used on earlier versions is no longer required It is replaced by a new electrode assembly without a resistor...

Страница 13: ...er drooling from spray gun Poor atomization of powder Increase the atomizing air pressure 3 Uneven pattern or voids in pattern Worn nozzle Replace the nozzle Impact fusion on interior surfaces of nozz...

Страница 14: ...threads of the cable well or rear support 2 4 Install a new resistor kit in the cable well as shown 5 Screw the cable adapter onto the cable well and tighten it securely 6 Insert the cable end throug...

Страница 15: ...ric grease from the insulating tube with a round brush whenever you remove and replace the electrostatic cable without installing a new resistor kit Warm two dielectric grease applicators by keeping t...

Страница 16: ...ans the part cannot be ordered separately The Description column gives the part name as well as its dimensions and other characteristics when appropriate Indentions show the relationships between asse...

Страница 17: ...flow 1 4 134732 S CLAMP tube powder 1 5 983120 S LOCK WASHER external split 10 2 6 981117 S SCREW round head 10 32 x 0 50 in 2 7 982002 S SCREW set square head M10 x 1 50 1 8 941181 S O RING silicone...

Страница 18: ...x 1 063 x 0 094 in 1 9 133726 S TUBE electrode 300 mm cooling air tube 1 10 134936 S WELL cable resistor high flow 1 11 137947 S TUBE powder high flow 1 12 138186 S KIT service resistor high flow 1 A...

Страница 19: ...NPE LF10 and NPE HF10 Powder Spray Guns 17 Part 108191C E 2003 Nordson Corporation 8 1 2 3 4 5 6 11 9 10 12 13 14 17 7 HF10 LF10 15 16 18 Figure 4 NPE LF10 and NPE HF10 Replacement Parts...

Страница 20: ...6 4 mm 0 25 in slot Gun Mounting Bar 249160 MOUNTING BAR gun Dielectric grease 247658 DIELECTRIC GREASE 10 cc applicator carton of 12 Note A Order the powder feed hose tubing in one foot increments N...

Отзывы: