© 2021 Nordson Corporation
8-18
60Hz Motor Weight Adjustment
See Figure 8-14
for steps 1 - 4 when replacing or retrofitting a 60Hz vibratory table motor
for the feed center.
FC 66% = 2 blades turned
60Hz = 156.5 lb. FC X 66% = 103.29 lb. FC
1. Remove the caps from both ends of the motor.
2. Place wrenches on the nuts located on both ends of the motor shaft.
3. Unscrew one nut and remove the weight blades from that end of the shaft. The
opposite nut will remain tight.
NOTE:
60Hz motors come with one weight blade already rotated at each end.
4.
Place an adjustable wrench on the shaft flat. Make sure that the wrench does not grip
the threaded area of the shaft. Use another wrench to unscrew the remaining nut.
Remove the weight blades from the end of the shaft.
Step 4
Step 1
Step 2 - 3
Step 4
Figure 8-14
Vibrator Weight Adjustment, 60Hz, Steps 1−4
Содержание Encore XL Powder
Страница 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Страница 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Страница 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Страница 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Страница 133: ...2021 Nordson Corporation 1607027 01 9 31 Parts 7 6 1 3 2 4 8 5 Figure 9 21 Sieve Parts Sieve with Angled Chute Shown...
Страница 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Страница 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Страница 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ...ON OFF...
Страница 154: ......