© 2021 Nordson Corporation
4-7
Empty (No Powder) Programming
1. Lower the lance assembly until the powder covers at least 25 mm (1 in.) of the level
sensor probe.
2. Raise the lance assembly so that the bottom of the level sensor probe is at least 25
mm (1 in.) away from the surface of the powder.
3. See Figure 4-3. Press the OUT OFF programming button until the LED ring slowly
flashes yellow.
4.
Release the button and the yellow light will go off. Empty programming is complete.
Full Programming
1. Lower the lance assembly until the powder covers at least 25 mm (1 in.) of the level
sensor probe.
2. See Figure 4-3. Press the OUT ON programming button until the LED ring switches
from flashing slowly to flashing quickly.
3. Release the button and the LED ring lights yellow continuously. Full programming is
complete.
Locking and Unlocking the Level Sensor
The level sensor can be locked to protect it from unauthorized adjustment.
NOTE:
The level sensor is shipped unlocked.
Task
Procedure
Locking
Simultaneously press the two programming buttons for 10 seconds in
the operating mode. When the LED ring light changes its status for a
brief moment, release the buttons. The level sensor is now locked.
Unlocking
Simultaneously press the two programming buttons for 10 seconds in
the operating mode. When the LED ring light changes its status for a
brief moment, release the buttons. The level sensor is now unlocked.
Operational Faults
If the sensor deviates from normal operation, check for and correct any of these possible
causes:
•
The difference between Empty and Full is not great enough. Reprogram the level
sensor.
• Empty programming was done while the probe was in the powder, or Full programming
was done while the probe was out of the powder.
• During Empty programming, the distance between the probe and the powder was too
short.
Содержание Encore XL Powder
Страница 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Страница 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Страница 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Страница 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Страница 133: ...2021 Nordson Corporation 1607027 01 9 31 Parts 7 6 1 3 2 4 8 5 Figure 9 21 Sieve Parts Sieve with Angled Chute Shown...
Страница 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Страница 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Страница 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ...ON OFF...
Страница 154: ......