© 2021 Nordson Corporation
4-6
Operational Faults (Red LED Flashing)
If either Empty or Full programming cannot be completed, the red LED flashes quickly.
Task
Procedure
Clearing a Fault
Clear the fault by either:
• pressing the programming button once, or
• cycling feed center power.
Correcting Faults
Check for and correct any of these possible causes for the fault:
•
The difference between Empty and Full is not great enough.
Reprogram the level sensor.
• Empty programming done while the probe was in the powder,
or Full programming done while the probe was out of the
powder.
• During Empty programming, the distance between the probe
and the powder was too short.
Two Button Level Sensor Probe Programming
When you program the level sensor probe, the powder feed center exhaust fan must be
on and the powder in the hopper must be thoroughly fluidized.
OUT OFF
Programming
Button
LED Ring
OUT ON
Programming
Button
Figure 4-3 Programming the Two Button Level Sensor Probe
LED Functions
LED Color
Status
Means
Green
On
Material not detected
Yellow
On
Material detected
Содержание Encore XL Powder
Страница 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Страница 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Страница 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Страница 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Страница 133: ...2021 Nordson Corporation 1607027 01 9 31 Parts 7 6 1 3 2 4 8 5 Figure 9 21 Sieve Parts Sieve with Angled Chute Shown...
Страница 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Страница 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Страница 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ...ON OFF...
Страница 154: ......