![Nordson EcoDry Series Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/nordson/ecodry-series/ecodry-series_customer-product-manual_1704300035.webp)
Nordson EcoDry
r
Series Induction Dryers with Touch Screen Controls
33
Part 1601306
−
02
E
2014 Nordson Corporation
PLC I/O Screen
This screen displays information for the various system inputs and outputs,
and their associated functions:
S
INPUT indicators
−
System inputs, their functions, and their
current status.
S
OUTPUT indicators
−
System outputs, and their functions, and their
current status.
S
Program code
−
Three part code that indicates system model, program
number and revision level. Example:
E10-1002-111710 = Ecodry, program # 1002, revision date 11-17-2010.
S
INV HOURS
−
Amount of time that the system inverter has been
conducting current to the coil.
S
RUN HOURS
−
Amount of time that the system has been in the RUN
mode, processing ends.
Figure 26 PLC I/O Screen