Nordson EcoDry
r
Series Induction Dryers with Touch Screen Controls
26
Part 1601306
−
02
E
2014 Nordson Corporation
Motion Detect Sensitivity Setting
The Motion Detect Sensitivity setting adjusts the time cycle of motion pulses
from the motion sensor. This can be useful for extreme line speeds (less
than 300 ends per minute or more than 1600 ends per minute).
The factory default setting is 300. Recommended settings per line speed
are:
S
Less than 750 ends/minute: 300
−
350
S
750
−
1500 ends/minute: 250
−
300
S
Greater than 1500 ends/minute: 200
−
250
1. On the Ramp/Motion Setup screen (Figure 19) touch the
Motion
Sensitivity
field and set the time with the keypad.
2. Touch the
ENT
key on the keypad to save your setting.
X
Figure 19
Ramp/Motion Setup Screen