Optional Status Contact
See Figure 10. The status contact is used in conjunction with the customer
interlock. The contact indicates when the dryer is off or in a fault condition.
The contact is off when:
S
The dryer has not been started (turned off).
S
Any fault on the operator panel is activated.
S
A run signal is received and motion is not detected by the Motion Sensor
before the External Interlock Timer expires. Refer to page 27 for timer
setting instructions.
Status Contact Connection: Terminal 20 Output Contact (output)
Motion Sensor
See Figure 11. The motion sensor mounting is designed to locate the
sensor in either of the two positions shown. Use the 12-O’clock position
when possible. If a rod cage entry is used with a rod at 12-O’clock or if an
overhead guide interferes with the sensor line of sight, reposition the motion
sensor to the 30
_
position as shown.
Remove the protective cap from the bottom of the motion sensor head.
Leave the cap attached to the sensor head for future use.
Adjust the motion sensor sensitivity as described in
Motion Sensor
Sensitivity Adjustment
30
_
Position
12-O’Clock
Position
Sensor
Head
Cap
Figure 11 Motion Sensor Position and Cover