background image

ProcessMate 6500 Temperature Control Unit

6

www.nordsonefd.com   [email protected]

   +1-401-431-7000    Sales and service of Nordson EFD dispensing systems are available worldwide.

Nordson EFD Product Safety Statement (continued)

Intended Use

Use of EFD equipment in ways other than those described in the documentation supplied with the equipment may 
result in injury to persons or damage to property. Some examples of unintended use of equipment include:

•  Using incompatible materials.
•  Making unauthorized modifications.
•  Removing or bypassing safety guards or interlocks.
•  Using incompatible or damaged parts.
•  Using unapproved auxiliary equipment.
•  Operating equipment in excess of maximum ratings.
•  Operating equipment in an explosive atmosphere.

Regulations and Approvals

Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for 
Nordson EFD equipment will be voided if instructions for installation, operation, and service are not followed. If the 
equipment is used in a manner not specified by Nordson EFD, the protection provided by the equipment may be 
impaired.

Personal Safety

To prevent injury, follow these instructions:

•  Do not operate or service equipment unless you are qualified.
•  Do not operate equipment unless safety guards, doors, and covers are intact and automatic interlocks are 

operating properly. Do not bypass or disarm any safety devices.

•  Keep clear of moving equipment. Before adjusting or servicing moving equipment, shut off the power supply 

and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent 
unexpected movement.

•  Make sure spray areas and other work areas are adequately ventilated.
•  When using a syringe barrel, always keep the dispensing end of the tip pointing towards the work and away 

from the body or face. Store syringe barrels with the tip pointing down when they are not in use.

•  Obtain and read the Safety Data Sheet (SDS) for all materials used. Follow the manufacturer’s instructions for 

safe handling and use of materials and use recommended personal protection devices.

•  Be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot 

surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise 
guarded for practical reasons.

•  Know where emergency stop buttons, shutoff valves, and fire extinguishers are located.
•  Wear hearing protection to protect against hearing loss that can be caused by exposure to vacuum exhaust 

port noise over long periods of time.

Содержание ProcessMate 6500

Страница 1: ...ProcessMate 6500 Temperature Control Unit Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www nordsonefd com...

Страница 2: ...have are answered in this manual However if you need assistance please do not hesitate to contact EFD or your authorized EFD distributor Detailed contact information is provided on the last page of th...

Страница 3: ...y 6 Fire Safety 7 Preventive Maintenance 7 Important Disposable Component Safety Information 8 Action in the Event of a Malfunction 8 Disposal 8 Specifications 9 Parts List 11 Installation 12 Unpack t...

Страница 4: ...CK Risk of electric shock Disconnect power before removing covers and or disconnect lock out and tag switches before servicing electrical equipment If you receive even a slight electrical shock shut d...

Страница 5: ...ng or servicing high pressure equipment A jet of high pressure fluid can cut like a knife and cause serious bodily injury amputation or death Fluids penetrating the skin can also cause toxic poisoning...

Страница 6: ...ate or service equipment unless you are qualified Do not operate equipment unless safety guards doors and covers are intact and automatic interlocks are operating properly Do not bypass or disarm any...

Страница 7: ...nnect switch first to prevent sparking Know where emergency stop buttons shutoff valves and fire extinguishers are located Preventive Maintenance As part of maintaining continuous trouble free use of...

Страница 8: ...ocal regulations after one time use Do not clean components with strong solvents MEK acetone THF etc Clean cartridge retainer systems and barrel loaders with mild detergents only To prevent fluid wast...

Страница 9: ...r details Temperature control 0 1 C from 10 40 C 50 104 F Ambient operating conditions Temperature 10 55 C 14 131 F Humidity 85 RH at 30 C non condensing Height above sea level 2000 m maximum 6562 ft...

Страница 10: ...s PBB Polybrominated Diphenyl Ethers PBDE External Electrical Connectors X 0 0 0 0 0 O EIP A EIP B EIP C SJ T11363 2006 Indicates that this toxic or hazardous substance contained in all the homogeneou...

Страница 11: ...ure control unit 1 2 7002004 Tubing 6 mm OD urethane blue 14 5 ft 4 50 m 3 7015199 25W universal power supply 1 4 7020364 Insulation 1 4 ID X 3 8 wall 6 ft 1 87 m 5 Thermocouple K type 1 6 Temperature...

Страница 12: ...e international plugs Attach the correct plug to match local power outlets b Connect the power cord into the back of the ProcessMate c Connect the power cord into your local power source 3 Connect Air...

Страница 13: ...e available from a variety of sources in many lengths Only K Type thermocouple leads should be used with the ProcessMate Using a different type will result in incorrect temperatures 5 Attach Process F...

Страница 14: ...cilities or machines which experience temperature fluctuations above and below the required process temperature require both hot and cold Configuration B Applications requiring both heating and chilli...

Страница 15: ...Temperature Control Unit Features Controls Front Rear Panels Digital display Power switch Air input Power cord Thermocouple Air switch Flow control knob To exhaust feed line Cold process feed line Hot...

Страница 16: ...CMW Communications writing enable disable indicator lights STOP Control stop indicator OUT Control output 1 2 indicators Advanced features NOT used by ProcessMate Change from Centigrade to Fahrenheit...

Страница 17: ...e sure the unit is unplugged when conducting maintenance on the unit Clean the unit with a damp sponge or cloth Use warm water and mild soap solution if required DO NOT allow drips or excess water ins...

Страница 18: ...er the entire material path syringe valve fittings etc leaving only the needle or exit point exposed The chamber should have a minimum of dead air space The less space inside the chamber the easier it...

Страница 19: ...sure to ensure that it is not varying If needed use the filter regulator EFD part 7016547 5 A slow drop or rise from the desired temperature usually over the course of several hours can be caused by m...

Страница 20: ...from this warranty exceed the purchase price of the equipment Before operation the user shall determine the suitability of this product for its intended use and the user assumes all risk and liabilit...

Отзывы: